YOKOGAWA 701870 CALIBRATION and YOKOGAWA 701870 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA 701870 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope Plug In?
Shop for Comparable Products on our
 used Oscilloscope Plug In page

 
   YOKOGAWA 701870   Description / Specification:    
YOKOGAWA 701870 Logic Input Module

The Yokogawa 701870 Logic Input Module is used with the DL708, DL708E and DL716 mainframes. Specifications. Number of input points: 16 (8 bits x 2). Maximum sample rate: 10 MS/s, except the response rate depends on the response time of the logic probe. Specifications with High-Speed Logic Probe (700986). Number of input points: 8. Input format: Non-isolated (the earth of each bit are common, the earth of the logic module and the earth of each bit are common). Maximum input voltage (At 1 kHz or less): 42 V (DC+ACpeak)(CAT I and CAT II, 30 Vrms), across probe tip and earth. Response time: 1 ms or less. Input impedance: 100 k-ohm or more. Threshold level approx: 1.4 V. Specifications with Isolation Logic Probe (700987). Number of input points: 8. Input format: Isolated (all bits are isolated). Maximum input voltage (across H and L of each bit): 250 Vrms (CAT I and II). Response time: During DC input: within 1 ms, During AC input: within 20 ms. Input impedance: approx. 100 k-ohm. Threshold level: During DC input: 6 VDC ± 50% (Hi level: 10 to 250 VDC, Lo level: 0 to 3 VDC), During AC input: 50 VAC ± 50% (Hi level: 80 to 250 VDC, Lo level: 0 to 20 VAC).



 

Standard Calibration $330.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA 701870. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your YOKOGAWA 701870 CALIBRATION and/or YOKOGAWA 701870 Logic Input Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: