YOKOGAWA WT3000-760302 CALIBRATION and YOKOGAWA WT3000-760302 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA WT3000-760302 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   YOKOGAWA WT3000-760302   Description / Specification:    
YOKOGAWA WT3000-760302 2-input Element Precision Power Analyzer

The Yokogawa 760302 WT3000 Precision Power Analyzer is the ideal measurement solution for applications such as product efficiency testing, engineering, R&D work on inverters, motor drives, lighting systems and electronic ballasts, UPS systems, aircraft power systems, transformer testing and other power conversion devices. Basic power accuracy of ± 0.02% of reading, DC and 0.1 Hz to 1 MHz measurement bandwidths, with two input elements, the WT3000 provides higher-accuracy measurement for inverter I/O efficiency. Features. Large, 8.4-inch LCD and the Range Indicator LEDs. 50 ms Data Storing Interval. Available GP-IB, Ethernet, RS-232 and USB. Specifications. Basic Power Accuracy: ±(0.02% of reading + 0.04% of range). Frequency Range: DC, 0.1 Hz to 1 MHz. Power factor influence when cos phi=0: 0.03% of S (S is reading value of apparent power)(phi is phase angle between voltage and current). Current Range Direct Input: 0.5/1/2/5/10/20/30 A, 5m/10m/20m/50m/100m/200m/500m/1/2 A (when crest factor is 3). Current Range External sensor Input: 50m/100m/200m/500m/1/2/5/10 V (when crest factor is 3). Guaranteed accuracy range for voltage and current ranges: 1% to 130%. Main measurement parameters: Voltage, current, active power, reactive power, apparent power, power factor, phase angle, peak voltage, peak current, crest factor. Motor Version provides analog or pulse signal from rotating sensor and torque meter can be input, and allows calculation of torque, revolution speed, mechanical power, synchronous speed, slip, motor efficiency, and total efficiency in a single unit. Options. -02, 30A input element. -20, 2A input element. -SV, Standard Version. -MV, Motor Version. /G6, Advanced Computation (IEC standard testing(requires 761922 software), harmonic, FFT, Waveform computation). /B5, Built-in Printer. /DT, Delta Calculation. /FQ, Add-on Frequency Measurement. /DA, 20ch D/A output. /V1, VGA Output. /C2, Serial (RS-232) Interface. /C12, USB port (PC). /C5, USB port (Peripheral). /C7, Ethernet function. /CC, Cycle by Cycle. /FL, Voltage Fluctuation, Flicker.



 

Standard Calibration $805.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA WT3000-760302. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your YOKOGAWA WT3000-760302 CALIBRATION and/or YOKOGAWA WT3000-760302 2-input Element Precision Power Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: