A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU 69097A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   ANRITSU 69097A   Description / Specification:    
ANRITSU 69097A 65 GHz Ultra Low Noise Synthesized CW Generator

The Anritsu 69097A 65 GHz Ultra Low Noise Synthesized CW Generator features 10 MHz to 20 GHz analog, step, and manual sweep capability. Output levels to +12 dBm and optional 0.1 Hz resolution. It provides AM and FM via external modulating signals or internal arbitrary waveform generators. The internal generators offer 7 modulating waveforms, including Gaussian noise, as well as user-defined arbitrary waveforms. Pulse modulation parameters can be set externally or by the internal pulse generator. Doublet, triplet, or quadruplet pulses make RADAR blind spot testing easy. Simultaneous synchronized modulations let you set complex signal scenarios across the entire frequency range. Specifications. Frequency Range: 0.01 to 65 GHz. CW mode Output: Twenty independent, presettable CW frequencies (FO to F9 and MO to M9). CW mode Accuracy: Same as internal or external 10 MHz time base. CW mode Resolution: 1 kHz (0.1 Hz with Option 11). Phase-locked step sweep mode Sweep width: Independently selected, 1 kHz (0.1 Hz with Option 11) to full range, every frequency step in sweep range is phase-locked. Phase-locked step sweep mode Resolution (Min. step size): 1 kHz (0.1 Hz with Option 11). Spurious signals Harmonic and harmonic related: <-30 dBc (10 to 50 MHz), <-40 dBc ( >50 MHz to <= 2 GHz), <-60 dBc ( >2 GHz to <= 20 GHz). Output power: +12 dBm (>= 0.01 to <2 GHz), +10 dBm (>= 2 to <=20 GHz), +2.5 dBm (>20 to <=40 GHz), +0 dBm (>40 to <=50 GHz), -2 dBm (>50 to <=65 GHz). Options. Option 2A, Step attenuator. Option 9, Rear panel RF output. Option 11, 0.1 Hz frequency resolution. Option 15, High power output. Option 16, High stability time base. Option 17, Delete front panel. Option 18, MM-wave bias. Option 19, SCPI programmability adds GPIB command mnemonics.



 

Standard Calibration $1,135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU 69097A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your ANRITSU 69097A CALIBRATION and/or ANRITSU 69097A 65 GHz Ultra Low Noise Synthesized CW Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: