EXTECH INSTRUMENTS EX470 REPAIR and EXTECH INSTRUMENTS EX470 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the EXTECH INSTRUMENTS EX470. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX470 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX470 (470)   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS EX470 True RMS Autoranging Multimeter with IR Thermometer

The Extech EX470 True RMS Autoranging Multimeter plus IR Thermometer measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode Test, and Continuity plus Thermocouple and Non-Contact IR Temperature.
Specifications.

DC Voltage Ranges: 400mV, 4V, 40V, 400V, 1000V.
DC Voltage Maximum Resolution: 0.1 mV.
DC Voltage Accuracy: ± (0.3% reading + 2 digits) @ 400 mV.

AC Voltage Ranges: 400mV, 4V, 40V, 400V, 750V.
AC Voltage Maximum Resolution: 0.1 mV.
AC Voltage Accuracy: ± (1.5% reading + 15 digits) @ 400 mV 50 to 400Hz.

DC Current Ranges: 400µA, 4000µA, 40mA, 400mA, 4 A, 20A.
DC Current Maximum Resolution: 0.1 µA.
DC Current Accuracy: ±(1.5% + 3d) @ 400µA, 4000µA, 40mA, 400mA.

AC Current Ranges: 400µA, 4000µA, 40mA, 400mA, 4A, 20A.
AC Current Maximum Resolution: 0.1 µA.
AC Current Accuracy: ±(1.8% reading + 8 digits) @ 400µA, 4000µA, 40mA, 400mA 50 to 400Hz.

Resistance Ranges: 400, 4k, 40k, 400k, 4M, 40Mohm.
Resistance Maximum Resolution: 0.1 ohm.
Resistance Accuracy: ± (0.8% reading + 4 digits) @ 400 ohm.

Capacitance Ranges: 40 nF, 400 nF, 4 µF, 40 µF, 100 µF.
Capacitance Maximum Resolution: 0.01 nF.
Capacitance Accuracy: ±(5.0% reading + 7 digits) @ 40 nF.

Temperature Type-K Ranges: -4 to 1382°F (-20 to 750°C ).
Temperature Maximum Resolution: 1°F/°C.
Temperature Accuracy: ±(3.0% reading + 3 digits) (probe accuracy not included).
Temperature (IR) Ranges: -58 to 518°F (-50 to 270°C ).
Temperature Maximum Resolution: 1°F/°C.
Temperature Accuracy: ±2.0% reading or ±2° C, ±4° F.

Frequency: 0.001Hz to 10MHz.
Frequency Accuracy: ±(1.5% reading + 5 digits) @ 5, 50 Hz range.

Duty Cycle: 0.1% to 99.9%.
Duty Cycle Maximum Resolution: 0.1%.
Duty Cycle Accuracy: ±(1.2% reading + 2 digits).

Diode Test: Test current of 0.3 mA typical, open circuit voltage 1.5V DC typical.

Continuity Check: Audible signal will sound if the resistance is less than 150 ohm (approx.), test current <0.7 mA.
Display: 4000 count backlit liquid crystal.



 

Standard Calibration $180.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX470. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your EXTECH INSTRUMENTS EX470 REPAIR and/or EXTECH INSTRUMENTS EX470 True RMS Autoranging Multimeter with IR Thermometer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: