FLUKE ESA612 CALIBRATION and FLUKE ESA612 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE ESA612 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   FLUKE ESA612   Description / Specification:    
FLUKE ESA612 Electrical Safety Analyzer

The Fuke ESA612 Electrical Safety Analyzer represents the next generation in test equipment for biomedical and clinical engineering professionals that perform field service on medical equipment throughout their facilities, in clinics, and anywhere onsite service is required. Portable, lightweight, and designed for operation in tight spaces, the ESA612 offers the functionality of a simulator, multimeter and electrical safety tester in a single test tool. With selection of two test loads, this versatile product can be used worldwide for compliance testing to preventative maintenance electrical safety standards of choice. The versatility of the multifaceted ESA612 tester is further expanded with optional automation software, which speeds and simplifies testing and provides high-end-analyzer productivity at software-level investment. Ansur-automated ESA612 standardizes test procedures, compares results to standards limits, and generates and stores reports for total digital data management. Specifications. Voltage Range (mains voltage): 90 V ac rms to 132 V ac rms, 180 V ac rms to 264 V ac rms. Voltage Range (accessible voltage): 0 V ac rms to 300 V ac rms. Voltage Accuracy: ± (2 % of reading + 0.2 V). Earth Resistance Modes: Two terminal. Earth Resistance Test current: > 200 mA ac. Earth Resistance Ranges: 0 to 2 ohms. Earth Resistance Accuracy: ± (2 % of reading + 0.015 ohm). Equipment Current Mode: ac rms. Equipment Current Range: 0 A to 20 A. Equipment Current Accuracy: ± (5 % of reading + (2 counts or 0.2 A, whichever is greater)). Leakage Current Modes: ac + dc (true rms), ac only, dc only. Insulation Resistance Ranges: 0.5 to 20 M-ohm, 20 to 100 M-ohm.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE ESA612. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your FLUKE ESA612 CALIBRATION and/or FLUKE ESA612 Electrical Safety Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: