EXTECH INSTRUMENTS EX430 CALIBRATION and EXTECH INSTRUMENTS EX430 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX430 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX430 (430)   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS EX430 True RMS Autoranging MultiMeter

The Extech EX430 Autoranging MultiMeter has a 4,000 count LCD display and temperature function. AC/DC Voltage & Current, Resistance, Capacitance, Frequency, Temperature, Duty Cycle, Diode/Continuity. Specifications. DC Voltage Ranges: 400mV, 4V, 40V, 400V, 1000V. DC Voltage Maximum Resolution: 0.1 mV. DC Voltage Accuracy: ± (0.3% reading + 2 digits) @ 400 mV. AC Voltage Ranges: 400mV, 4V, 40V, 400V, 750V. AC Voltage Maximum Resolution: 0.1 mV. AC Voltage Accuracy: ± (1.5% reading + 15 digits) @ 400 mV 50 to 400Hz. DC Current Ranges: 400µA, 4000µA, 40mA, 400mA, 4 A, 20A. DC Current Maximum Resolution: 0.1 µA. DC Current Accuracy: ±(1.5% + 3d) @ 400µA, 4000µA, 40mA, 400mA. AC Current Ranges: 400µA, 4000µA, 40mA, 400mA, 4A, 20A. AC Current Maximum Resolution: 0.1 µA. AC Current Accuracy: ±(1.8% reading + 8 digits) @ 400µA, 4000µA, 40mA, 400mA 50 to 400Hz. Resistance Ranges: 400, 4k, 40k, 400k, 4M, 40Mohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: ± (0.8% reading + 4 digits) @ 400 ohm. Capacitance Ranges: 40 nF, 400 nF, 4 µF, 40 µF, 100 µF. Capacitance Maximum Resolution: 0.01 nF. Capacitance Accuracy: ±(5.0% reading + 7 digits) @ 40 nF. Frequency: 0.001Hz to 10MHz. Frequency Accuracy: ±(1.5% reading + 5 digits) @ 5, 50 Hz range. Duty Cycle: 0.1% to 99.9%. Duty Cycle Maximum Resolution: 0.1%. Duty Cycle Accuracy: ±(1.2% reading + 2 digits). Temperature Ranges: -4 to 1382°F (-20 to 750°C ). Temperature Maximum Resolution: 1°F/°C. Temperature Accuracy: ±(3.0% reading + 3 digits) (probe accuracy not included). Diode Test: Test current of 0.3mA typical, open circuit voltage 1.5V DC typical. Continuity Check: Audible signal will sound if the resistance is less than 150 ohm (approx.), test current <0.3mA. Display: 4000 count backlit liquid crystal.



 

Standard Calibration $75.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX430. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your EXTECH INSTRUMENTS EX430 CALIBRATION and/or EXTECH INSTRUMENTS EX430 True RMS Autoranging MultiMeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: