STANFORD RESEARCH SYSTEMS LDC500 CALIBRATION and STANFORD RESEARCH SYSTEMS LDC500 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the STANFORD RESEARCH SYSTEMS LDC500 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Diode Controller?
Shop for Comparable Products on our
 used Laser Diode Controller page

 
   STANFORD RESEARCH SYSTEMS LDC500   Description / Specification:    
STANFORD RESEARCH SYSTEMS LDC500 100 mA Laser Diode Controller

The SRS LDC500 Laser Diode Controller is an ideal instrument for controlling the current and temperature of your laser diodes. It has the performance and features you expect from instruments costing twice as much. The LDC500 has up to 100 mA of output current with less than 0.3 µA of rms noise. The SRS LDC500 is a 36 W high-precision temperature controller with standard computer interfaces, including Ethernet. It has multiple laser diode protection features, including slow start turn-on, adjustable current limits, and adjustable compliance voltage. Specifications. Current Source Range: 0 to 100 mA, 0 to 50 mA. Setpoint resolution: 1 µA. Accuracy: ±0.02 % of full scale. Output impedance: >1 M-ohm (DC). Thermal Stability: <10 ppm/°C. Noise (10 Hz to 1 MHz): 0.9 µA rms (high range / high BW), 0.9 µA rms (high range / low BW), 0.5 µA rms (low range / high BW), 0.3 µA rms (low range / low BW). Compliance voltage Range: 0 to 10 V, programmable. Resolution: 10 mV. Accuracy: 0.2 V. Monitor Photodiode Bias voltage: 0 to 5 V, programmable. PD current range: 0 to 5,000 µA. Temperature Control range: IC sensor -55 °C to +150 °C, Resistor sensor -150 °C to +250 °C (10 ohm to 500 k-ohm). Setpoint resolution Temperature: 0.001 °C. TEC Output Source type: Linear, bipolar current source. Current range: -4.5 A to +4.5 A.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the STANFORD RESEARCH SYSTEMS LDC500. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your STANFORD RESEARCH SYSTEMS LDC500 CALIBRATION and/or STANFORD RESEARCH SYSTEMS LDC500 100 mA Laser Diode Controller REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: