STANFORD RESEARCH SYSTEMS DG645 CALIBRATION and STANFORD RESEARCH SYSTEMS DG645 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the STANFORD RESEARCH SYSTEMS DG645 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Pulse Generator?
Shop for Comparable Products on our
 used Pulse Generator page or new Pulse Generator page

 
   STANFORD RESEARCH SYSTEMS DG645   Description / Specification:    
STANFORD RESEARCH SYSTEMS DG645 4/8 Ch Digital Delay/Pulse Generator

The SRS DG645 is a versatile digital delay/pulse generator that provides precisely defined pulses at repetition rates up to 10 MHz. The instrument offers several improvements over older designs — lower jitter, higher accuracy, faster trigger rates, and more outputs. The DG645 also has Ethernet, GPIB and RS-232 interfaces for computer or network control of the instrument. The SRS DG645 eliminates timing indeterminacy by measuring the timing of triggers with respect to the internal clock and compensating the analog delays. This approach reduces the jitter by about 100× and allows the internal rate generator to operate at any rate - not just a sub-multiple of the clock frequency. Specifications. Delay Channels: 4 independent pulses controlled in position and width. 8 delay channels (optional). Range: 0 to 2000 s. Resolution: 5 ps. Accuracy: 1 ns + (timebase error × delay). Trigger delay: 85 ns (ext. trig. to T0 output). External Trigger Rate: DC to 1/(100 ns + longest delay), (maximum of 10 MHz). Threshold: ±3.50 VDC. Internal Rate Generator Trigger modes: Continuous, line or single shot. Rate: 100 µHz to 10 MHz. Resolution: 1 µHz. Option 01, Eight delay channels (5 V) . Option 02, Eight delay channels (30 V). Option 03, Combinatorial outputs. Option 04, OCXO timebase. Option 05, Rubidium timebase.



 

Standard Calibration $575.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the STANFORD RESEARCH SYSTEMS DG645. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your STANFORD RESEARCH SYSTEMS DG645 CALIBRATION and/or STANFORD RESEARCH SYSTEMS DG645 4/8 Ch Digital Delay/Pulse Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: