TEKTRONIX MSO2014B CALIBRATION and TEKTRONIX MSO2014B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX MSO2014B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX MSO2014B   Description / Specification:    
TEKTRONIX MSO2014B 4+16 Ch 100 MHz Mixed Signal Oscilloscope

The Tektronix MSO2014B 100 MHz 4+16 channel Mixed Signal Oscilloscope lets you quickly find and diagnose problems in complex designs with up to 20 channels for analyzing analog and digital signals. Specifications. Bandwidth: 100 MHz. Maximum Sample Rate: 1.0 GS/s. Calculated Rise Time: 3.5 ns. Hardware Bandwidth Limits: 20 MHz. Input Coupling: AC, DC, GND. Input Impedance: 1 M-Ohm ±2%, 11.5 pF ±2 pF. Input Sensitivity Range: 2 mV/div to 5 V/div. Vertical Resolution 8 bits. Maximum Input Voltage, 1 M-Ohm: 300 VRMS with peaks <= ±450 V. DC Gain Accuracy (with offset set to 0 V): ±3% for 10 mV/div to 5 V/div, ±4% for 2 mV/div to 5 mV/div. Vertical System Digital Channels; Input Channels: 16 Digital (D15 to D0). Thresholds: Threshold per set of 8 channels. Threshold Selections: TTL, CMOS, ECL, PECL, User Defined. User-defined Threshold Range: ±20 V. Maximum Input Voltage: ±40 V. Threshold Accuracy: ±(100 mV +3% of threshold setting). Maximum Input Dynamic Range: 80 Vpk-pk (threshold setting dependent). Minimum Voltage Swing: 500 mVpk-pk. Input Impedance: 101 k ohm. Probe Loading: 8 pF. Vertical Resolution: 1 bit. Horizontal System Digital Channels; Maximum Sample Rate (when using any of channels D7-D0): 1 GS/s (1 ns resolution). Maximum Sample Rate (when using any of channels D15-D8): 500 MS/s (2 ns resolution). Maximum Record Length (all channels): 1 Mpoints. Minimum Detectable Pulse Width: 5 ns. Channel-to-Channel Skew: 2 ns typical. Horizontal System Analog Channels; Maximum Sample Rate (all channels): 1 GS/s. Maximum Record Length (all channels): 1 Mpoints. Maximum Duration of Time Captured at Highest Sample Rate (all channels): 1 ms. Time-base Range (s/div) 2 ns to 100 s. Time-base Delay Time Range: -10 divisions to 5000 s. Channel-to-Channel Deskew Range: ±100 ns. Time-base Accuracy: ±25 ppm. Display Type: 7 in. (180 mm) liquid crystal TFT color display.



 

Standard Calibration $190.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX MSO2014B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TEKTRONIX MSO2014B CALIBRATION and/or TEKTRONIX MSO2014B 4+16 Ch 100 MHz Mixed Signal Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: