EXTECH INSTRUMENTS MP530 CALIBRATION and EXTECH INSTRUMENTS MP530 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS MP530 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS MP530   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS MP530 Autoranging Digital MultiMeter with RS-232 & Temp

The Extech MP530 Autoranging Digital MultiMeter with RS-232 & Temp features a backlit 5000 count LCD display for high resolution. Smart auto power off is disabled if signal is present at test leads. Measurement functions include AC/DC Voltage and Current, Resistance, Frequency, Capacitance, Diode and Continuity. Specifications. AC Voltage Ranges: 50mV, 500mV, 5V, 50V, 500V, 1000V. AC Voltage Maximum Resolution: 0.01 mV. AC Voltage Basic Accuracy (%rdg+digits): ±(0.5%+3d). DC Voltage Ranges: 50mV, 500mV, 5V, 50V, 500V, 1000V. DC Voltage Maximum Resolution: 0.01 mV. DC Voltage Basic Accuracy (%rdg+digits): ±(0.08%+2d). AC Current Ranges: 500µA, 5000µA, 50mA, 500mA, 5A, 10A. AC Current Maximum Resolution: 0.1 µA. AC Current Basic Accuracy (%rdg+digits): ±(0.6% + 3d). DC Current Ranges: 500µA, 5000µA, 50mA, 500mA, 5A, 10A. DC Current Maximum Resolution: 0.1 µA. DC Current Basic Accuracy (%rdg+digits): ±(0.2% + 4d). Resistance Ranges: 50, 500k, 5k, 50k, 500k, 5M, 50Mohm. Resistance Maximum Resolution: 0.01 ohm. Resistance Basic Accuracy (%rdg+digits): ±(0.1% + 2d). Capacitance Ranges: 50 nF ,500 nF, 5 µF, 50 µF, 500 µF, 9999 µF. Capacitance Maximum Resolution: 0.01 nF. Capacitance Basic Accuracy (%rdg+digits): ±(0.8% + 3d). Frequency Ranges: 0.001 Hz to 125 kHz. Frequency Maximum Resolution: 0.001 Hz. Frequency Basic Accuracy (%rdg+digits): ±(0.01%+2d). Temperature Ranges: -58 to 1832°F (-50 to 1000°C ). Temperature Maximum Resolution: 1°F/°C. Temperature Basic Accuracy (%rdg+digits): ±(0.3%+3d).



 

Standard Calibration $180.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS MP530. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your EXTECH INSTRUMENTS MP530 CALIBRATION and/or EXTECH INSTRUMENTS MP530 Autoranging Digital MultiMeter with RS-232 & Temp REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: