ASSOCIATED RESEARCH 8106 REPAIR and ASSOCIATED RESEARCH 8106 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ASSOCIATED RESEARCH 8106. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ASSOCIATED RESEARCH 8106 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 8106 (OMNIA 6)   Description / Specification:    
ASSOCIATED RESEARCH 8106 5KV AC/DC Hipot / IR / Ground Bond / Continuity Tester

The Associated Research 8106 OMNIA 6 is a 5 kVAC/DC Hipot tester with a built-in Insulation Resistance, Ground Bond, Run Test, Line Leakage and Continuity Tester. The AR 8106 uses four-wire measurement technique to factor out test lead resistance, making measurements more accurate. The Milliohm Offset features allows the operator to factor out additional lead and fixture resistance. It has patented SmartGFI™ which disables the instrument’s output voltage in less than 1 millisecond if excessive leakage to ground is detected. If enabled, SmartGFI™ automatically detects if the DUT is floating or grounding and turns ON or OFF accordingly. The OMNIA simultaneously monitors real and total current in AC Hipot mode on the same screen.Specifications. Dielectric Withstand Test Mode Output Rating: 5000 V @ 40 mA AC, 5000 V @ 20 mA DC. Output Adjustment Range: 0 - 5.00 KV AC, 0 - 5.00 KV DC. Voltage Setting Resolution: 1 V. Voltage Setting Accuracy: ± (2% of setting + 5 V). HI and LO-Limit AC Total Range: 0.000 - 9.999 mA, Resolution 0.001 mA. HI and LO-Limit DC Range: 0.0 - 999.9 µA, Resolution 0.1 µA. Arc Detection Range: 1 – 9. Ground Continuity Current: DC 0.1 A ± 0.01 A (Max. ground Resistance 1 ohm ± 0.1 ohm, fixed). AC Output Waveform: Sine Wave, Crest Factor = 1.3 - 1.5. Output Frequency Range: 50 or 60 Hz, User Selectable. Insulation Resistance Test Mode Voltage Setting Range: 50 - 1000 VDC, Resolution 1 Volt, Accuracy ± (2% of setting + 2 counts). Resistance Display Range: 0.05 M-ohm – 50,000 M-ohm (4 Digit, Auto Ranging). Ground Bond Test Mode Output Voltage Range: 3.00 – 8.00 VAC, Resolution 0.01 V, Accuracy ± (2 % of setting + 0.03V) O.C. Condition. Run Test Mode DUT Power Voltage: 0 – 277 VAC Single Phase Unbalanced (One Hot or Line conductor and One Neutral). Current: 15AAC max continuous. Line Leakage Test Mode: Voltage 0 – 277 VAC, Current 15AAC max continuous. Memory: 50 memories, 30 step/memory. Interface: Standard USB/RS-232, GPIB or Ethernet. Graphic Display: 320 X 240 Monographic LCD. Options. Scanning Matrix, 4 or 8 port high voltage switching matrix with continuity.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 8106. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your ASSOCIATED RESEARCH 8106 REPAIR and/or ASSOCIATED RESEARCH 8106 5KV AC/DC Hipot / IR / Ground Bond / Continuity Tester CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: