A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ ZVA8.10 Calibration, onsite calibration may be available.
We specialize in quick turnaround times and we can handle expedited deliveries upon request.
Need another Network Analyzer, SNA, VNA? Shop for Comparable Products on our
used Network Analyzer, SNA, VNA page
or
new Network Analyzer, SNA, VNA page
More
|
|
|
The R&S ZVA8 (1145.1110.10) 8 GHz Vector Network Analyzer is an ideal choice for measurements on active and passive components and modules, which require high performance and wide versatility. It instruments support scalar and vector measurements on mixers and converters (linear and nonlinear) and noise measurements on amplifiers as well as pulsed measurements for aerospace and defense applications. Specifications. Number of test ports: 4. Frequency range: 300 kHz to 8 GHz. Frequency resolution: 1 Hz. Number of measurement points: 1 to 60001 (user-selectable). Measurement bandwidths: 1/2/5 steps, 1 Hz to 1 MHz. Measurement time per test point: < 3.5 µs (CW mode, 1 MHz measurement bandwidth). Switching time Between channels with no more than 2001 points: < 1 ms. Max. dynamic range at (100 MHz to 4 GHz): 130 dB, typ. > 140 dB. Max. Output power at test port (50 MHz to 4 GHz): –40 dBm to +13 dBm, typ. –45 dBm to +15 dBm. Impedance: 50 ohm. Test ports: type N, female. Options. ZVA8-B16 (1164.0209.10), Direct Generator/Receiver Access. ZVA8-B21 (1164.0009.02), Generator Step Attenuator Port 1. ZVA8-B22 (1164.0015.02), Generator Step Attenuator Port 2. ZVA8-B23 (1164.0021.02), Generator Step Attenuator Port 3. ZVA8-B24 (1164.0038.02), Generator Step Attenuator Port 4. ZVA8-B31 (1164.0044.02), Receiver Step Attenuator Port 1. ZVA8-B32 (1164.0050.02), Receiver Step Attenuator Port 2. ZVA8-B33 (1164.0067.02), Receiver Step Attenuator Port 3. ZVA8-B34 (1164.0073.02), Receiver Step Attenuator Port 4. ZVAB-B4 (1164.1757.02), Oven Quartz (OCXO). ZVAB-B14 (1305.6306.02), Universal Control Interface I/O Port. ZVAB-K2 (1164.1657.02), Time Domain. ZVA-K4 (1164.1863.02), Frequency Conversion. ZVA-K5 (1311.3128.02), Mixer Phase Measurement. ZVA-K6 (1164.1540.02), True Differential Mode. ZVA-K7 (1164.1511.02), Pulsed Measurements. ZVA-B7 (1164.1492.03), Pulsed Measurements with increased recording time. ZVA-K8 (1307.7022.02), Converter Control Software. ZVA-K9 (1311.3128.02), Mixer Delay without LO Access. ZVA-K17 (1164.1070.02), 5 MHz Receiver Bandwidth. ZVA-K27 (1164.1892.02), Internal Pulse Generators. ZVA-K30 (1164.1828.02), Noise Figure Measurements.
|