JDSU E4136MA CALIBRATION and JDSU E4136MA REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the JDSU E4136MA Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another OTDR? Shop for Comparable Products on our   new OTDR page

 
   JDSU E4136MA (MTS4136MA)   Description / Specification:    
JDSU E4136MA Metro Access 1310/1550/1625 nm OTDR Module

The JDSU E4136MA Metro access 1310/1550/1625 nm OTDR module meets the challenges of commissioning a complete metro ring, troubleshooting a bend in a distribution frame, or qualifying high-port-count optical splitters in passive optical networks (PON). Its impressive technical specifications combined with a wide range of test functions give technicians with the best solution to more efficiently deploy or repair fiber links in the field. It isused with the T-BERD/MTS-2000, -4000, -5800 platforms. Standard testing features include: Automatic macrobend detection, Summary results table with pass/fail analysis, Bidirectional OTDR analysis, Fast-Report - onboard report generation. Specifications. Distance measurement; Mode: Automatic or dual cursor. Display range: 0.5 up to 260 km. Cursor resolution: 1 cm. Sampling resolution: 4 cm. Accuracy: ±1 m ±sampling resolution ±1.10^-5 x distance (excluding group index uncertainties). Attenuation Measurement; Mode: Automatic, manual, 2-point, 5-point, and LSA. Display range: 1.25 to 55 dB. Display resolution: 0.001 dB. Cursor resolution: 0.001 dB. Linearity: ±0.03 dB/dB. Threshold: 0.01 to 5.99 dB in 0.01 dB steps. Reflectance/ORL Measurements; Reflectance accuracy: ±2 dB. Display resolution: 0.01 dB. Threshold: -11 to -99 dB in 1 dB steps. Central Wavelength: 1310 ±20 nm, 1550 ±20 nm, 1625 ±10 nm. Event Dead Zone: 0.9 m. Source and Broadband Power Meter (optional), CW source output power level: -3.5 dBm.



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the JDSU E4136MA. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your JDSU E4136MA CALIBRATION and/or JDSU E4136MA Metro Access 1310/1550/1625 nm OTDR Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: