EXFO IQS-2600B CALIBRATION and EXFO IQS-2600B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXFO IQS-2600B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
   EXFO IQS-2600B   Description / Specification:    
EXFO IQS-2600B 1510 to 1612 nm Tunable Laser Source Module

The Exfo IQS-2600B Tunable Laser Source Module for the IQS-500 or IQS-600 system is ideal for complete characterization of fiber-optic filters, multiplexers and other dense WDM components. They are the logical choice for instrumentation calibration and for measuring wavelength-dependent gain, noise contribution and the saturation properties of EDFAs. This second-generation tunable erbium-doped fiber laser delivers exacting wavelength accuracy for long periods of use. Wavelength can now be tuned over a wide range of1510 nm to 1612 nm. Output power is greater than 0 dBm over the critical 1515 nm to 1610 nm range. The tunable laser source integrates both a monitor output port and a main output port. The monitor port, which is essentially a 5 % tap from the laser cavity, is useful for real-time wavelength monitoring in tests where optimum wavelength accuracy plays a major role. In addition, the main output is regulated in output power and can be attenuated over a 10 dB range. Specifications. Wavelength Range: 1510 to 1612 nm. Display resolution: 1 pm. Effective spectral linewidth FWHM: 1.3 GHz (typical). Uncertainty: ±15 pm. Sweep rate: 50 nm/s (maximum), 2 nm/s (minimum). Tuning time: 75 ms (typical). Output power: >= 0 dBm (1515 nm to 1610 nm). Stability 15 minutes: ±0.005 dB (delta = 0.01). Signal to total SSE: >= 45 dB. Attenuation range: 10 dB. Linearity with attenuation: ±0.3 dB (typical). Output fiber type: SMF-28.



 

Standard Calibration $480.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXFO IQS-2600B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Time
Average time for the wave train to lose its phase realtionships

Fiber Bragg Grating (FBG)
A fiber Bragg grating (FBG) is a type of distributed Bragg reflector constructed in a short segment of optical fiber that reflects particular wavelengths of light and transmits all others. This is achieved by adding a periodic variation to the refractive index of the fiber core, which generates a wavelength specific dielectric mirror. A fiber Bragg grating can therefore be used as an inline optical filter to block certain wavelengths, or as a wavelength-specific reflector.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another. Adding information into pulses of light.

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, such as a fiber optic transmission system, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your EXFO IQS-2600B CALIBRATION and/or EXFO IQS-2600B 1510 to 1612 nm Tunable Laser Source Module REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: