ROHDE & SCHWARZ ZVA24.26 CALIBRATION and ROHDE & SCHWARZ ZVA24.26 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ ZVA24.26 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ROHDE & SCHWARZ ZVA24.26 (1145.1110.26)   Description / Specification:   Spec Sheet 
ROHDE & SCHWARZ ZVA24.26 24 GHz Vector Network Analyzer, 4 Port, 50 Ohm

The R&S ZVA24 (1145.1110.26) 24 GHz Vector Network Analyzer is an ideal choice for measurements on active and passive components and modules, which require high performance and wide versatility. It instruments support scalar and vector measurements on mixers and converters (linear and nonlinear) and noise measurements on amplifiers as well as pulsed measurements for aerospace and defense applications. Specifications. Number of test ports: 4. Frequency range: 10 MHz to 24 GHz. Frequency resolution: 1 Hz. Number of measurement points: 1 to 60001 (user-selectable). Measurement bandwidths: 1/2/5 steps, 1 Hz to 1 MHz. Measurement time per test point: < 3.5 µs (CW mode, 1 MHz measurement bandwidth). Switching time Between channels with no more than 2001 points: < 1 ms. Max. dynamic range: >130 dB, typ. 135 dB (2 GHz to 13 GHz). Max. Output power at test port: +13 dBm, typ. +15 dBm (10 MHz to 13 GHz). Impedance: 50 ohm. Test ports: 3.5 mm, male, ruggedized. Options. ZVA24-B16 (1164.0209.26), Direct Generator/Receiver Access. ZVA24-B21 (1164.0109.02), Generator Step Attenuator Port 1. ZVA24-B22 (1164.0115.02), Generator Step Attenuator Port 2. ZVA24-B23 (1164.0121.02), Generator Step Attenuator Port 3. ZVA24-B24 (1164.0138.02), Generator Step Attenuator Port 4. ZVA24-B31 (1164.0144.02), Receiver Step Attenuator Port 1. ZVA24-B32 (1164.0150.02), Receiver Step Attenuator Port 2. ZVA24-B33 (1164.0167.02), Receiver Step Attenuator Port 3. ZVA24-B34 (1164.0173.02), Receiver Step Attenuator Port 4. ZVAB-B4 (1164.1757.02), Oven Quartz (OCXO). ZVAB-B14 (1305.6306.02), Universal Control Interface I/O Port. ZVAB-K2 (1164.1657.02), Time Domain. ZVA-K4 (1164.1863.02), Frequency Conversion. ZVA-K5 (1311.3128.02), Mixer Phase Measurement. ZVA-K6 (1164.1540.02), True Differential Mode. ZVA-K7 (1164.1511.02), Pulsed Measurements. ZVA-B7 (1164.1492.03), Pulsed Measurements with increased recording time. ZVA-K8 (1307.7022.02), Converter Control Software. ZVA-K9 (1311.3128.02), Mixer Delay without LO Access. ZVA-K17 (1164.1070.02), 5 MHz Receiver Bandwidth. ZVA-K27 (1164.1892.02), Internal Pulse Generators. ZVA-K30 (1164.1828.02), Noise Figure Measurements.



 

Standard Calibration $730.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ ZVA24.26. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your ROHDE & SCHWARZ ZVA24.26 CALIBRATION and/or ROHDE & SCHWARZ ZVA24.26 24 GHz Vector Network Analyzer, 4 Port, 50 Ohm REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: