FIBERPRO PL2000 CALIBRATION and FIBERPRO PL2000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FIBERPRO PL2000 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Polarization Meter?
Shop for Comparable Products on our
 used Polarization Meter page or new Polarization Meter page

 
   FIBERPRO PL2000   Description / Specification:    
FIBERPRO PL2000 PDL Meter

The FIBERPRO PL2000 PDL Meter measures Polarization Dependent Loss (PDL) and Insertion Loss (IL) of optical components simultaneously as a function of wavelength (wavelength-swept measurement). In addition, optical power measurement function is provided. The PL2000 is an ideal solution for measuring PDL and IL of DWDM components efficiently and accurately. Specifications. Operating Wavelength Range PDL: 1310 to 1620 nm. Operating Wavelength Range IL: 1310 nm, 1520 to 1620 nm. Resolution: 0.1 dB, 0.01 dB, 0.001 dB. PDL Accuracy: <= ±(0.010 + 5% of PDL) dB maximim, <= ±(0.010 + 2% of PDL) dB typical. IL Accuracy: <= ±(0.1 + 2% of IL) dB maximum. PDL / IL Measurement speed: 0.1 sec. Typ. PDL Range: 0 to 5 dB. IL Range: 50 dB. Power Accuracy: ±0.2 dB @ -10 dBm. Power Range: +3 dBm to -57 dBm.



 

Standard Calibration $700.00 *
*This is a Web introductory price for one calibration of the FIBERPRO PL2000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chirp
A change in the optical frequency caused by direct modulation of the laser. A chirp is a signal in which the frequency increases ('up-chirp') or decreases ('down-chirp') with time. In some sources, the term chirp is used interchangeably with sweep signal.

Isolation
The extent to which optical power from one signal path is prevented from reaching another signal path.

Polarization Extinction Ratio
Polarization Extinction Ratio is the ratio of optical power in the slow axis of the polarization maintaining fiber to optical power in the fast axis within a specified wavelength range.

Sidemode Suppression Ratio
Sidemode Suppression Ratio is the ratio of average signal power to the optical power of the highest sidemode within a distance from 0.1 to 6 GHz to the signal’s optical frequency, expressed in dB.

Wavelength Stability
Wavelength Stability is the change of wavelength during given time span, expressed as ± half the span between the maximum and the minimum of all actual wavelengths.


Please contact us for your FIBERPRO PL2000 CALIBRATION and/or FIBERPRO PL2000 PDL Meter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*