ASSOCIATED RESEARCH 3665 CALIBRATION and ASSOCIATED RESEARCH 3665 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ASSOCIATED RESEARCH 3665 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ASSOCIATED RESEARCH 3665   Description / Specification:    
ASSOCIATED RESEARCH 3665 5kV AC, 6kV DC Hipot with Ground Continuity Check

The Associated Research 3665 5KV AC, 6KV DC Hipot with Ground Continuity Check has an enhanced Graphic LCD and entry-level automation with an RS-232 interface. Features. Remote Safety Interlock feature prevents the high-voltage from being activated without the interlock enabled. Electronic Ramp and Dwell timers for more consistent and reliable testing. Interconnects with an Associated Research Ground Bond tester to form a complete test system. Digitally controlled arc detection circuit allows the operator to program sensitivity levels for detecting arcs. Minimum and maximum trip settings for safer and more accurate testing. Specifications. Dielectric Withstand Test Mode Output Rating: 5000 V @ 20 mA AC, 6000 V @ 7.5 mA DC. Voltage Setting Range: 0 - 5.00 KV AC, 0 - 6.00 KV DC. Voltage Setting Resolution: 0.01 KV. Voltage Setting Accuracy: ± (2% of setting + 5 V). Maximum Limit AC Range: 0.00 - 20.00 mA, Resolution 0.01 mA. Maximum Limit DC Range: 0 - 7500 µA, Resolution 1 µA. Maximum Limit Accuracy: AC and DC ± (2% of setting + 2 counts). AC Voltage Waveform: Sine Wave, Crest Factor = 1.3 - 1.5, <2% THD. Output Frequency Range: 50 or 60 HZ, User Selectable. Ground Continuity Current: DC 0.1 A ± 0.01 A, fixed.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ASSOCIATED RESEARCH 3665. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your ASSOCIATED RESEARCH 3665 CALIBRATION and/or ASSOCIATED RESEARCH 3665 5kV AC, 6kV DC Hipot with Ground Continuity Check REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: