VITREK V63 CALIBRATION and VITREK V63 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the VITREK V63 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   VITREK V63   Description / Specification:    
VITREK V63 5KV AC, 6KV DC Hipot with IR and Ground Continuity Check

The Vitrek V63 5KV AC, 6KV DC Hipot Tester with Insulation Resistance and Ground Continuity comes loaded with standard features that help you automate the task at hand. With the built-in fully bidirectional RS232 interface, you can download and run test sequences, as well as retrieve test results and data. The PCL Interface 9-pin D-sub connector with outputs of Testing, Pass, Fail with inputs of Start, Reset. Standard features to assist in automated testing and data storage include: Built-in 160 Step Test Memory, Programmable Ramp & Dwell Times, and Programmable Output Voltages and Limits. Specifications. Voltage Range AC: 0.100KV to 5.000KV. Voltage Setting AC: 5 Volt Increments. Voltage Regulation (Line & Load) AC: 1% + 5V. Voltage Accuracy AC: 1% of reading + 10V. Current Sourcing AC: 30 to 40mA (above 500V, 180sec. max.), 0 to 29.99mA (above 500V, continuous), 0 to 10mA (below 500V, continuous). Current Limit Range AC: 0.10 to 40mA, 0.02mA/step. Voltage Range DC: 0.100KV to 6.000KV. Voltage Setting DC: 5 Volt Increments. Voltage Regulation (Line & Load) DC: 1% + 5V. Voltage Accuracy DC: 1% of reading + 10V. Current Sourcing DC: 0 to 10mA (above 500V, continuous), 0 to 2mA (below 500V, continuous). Current Limit Range DC: 0.10 to 10mA, 0.01mA/step. Current Accuracy DC: 1.5% of reading + 50µA . Insulation Resistance DC Output Voltage: 50V / 100V 500V / 1000V. Insulation Resistance Accuracy 50V / 100V: 1 to 50M-ohm: 5% of reading, 51 to 200 M-ohm: 10% of reading, 201 to 2000 M-ohm: 20% of reading. Insulation Resistance Accuracy 500V / 1000V: 1 to 500 M-ohm: 5% of reading, 501 to 2000 M-ohm: 10% of reading, 2001 to 9900 M-ohm: 20% of reading. Continuity Measurement Test Current: 100 mA. Continuity Measurement Resistance Range: 0.001 to 1.500 ohm. Continuity Measurement Resistance Accuracy: ±0.075 ohm. GPIB Option GP-60, IEEE-488 interface.



 

Standard Calibration $575.00 *
*This is a Web introductory price for one calibration of the VITREK V63. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your VITREK V63 CALIBRATION and/or VITREK V63 5KV AC, 6KV DC Hipot with IR and Ground Continuity Check REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: