AEMC 6505 CALIBRATION and AEMC 6505 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC 6505 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC 6505 (2130.18)   Description / Specification:    
AEMC 6505 5000V Digital/Analog Megohmmeter

The AEMC 6505 5000V Digital/Analog Megohmmeter is designed to test insulation on cables, transformers, motors, generators, insulators and wiring installations. Rugged weatherproof megohmmeter is ideal for high resistance or absorption tests, spot reading tests, Dielectric Absorption Ratio (DAR & Polarization Index (PI) tests & more. Specifications. Test Voltage: 500V (30 kohm to 2000 Mohm), 1000V (100 kohm to 4000 Mohm), 2500V (100 kohm to 10,000 Mohm), 5000V (300 kohm to 10,000 Mohm). User Selectable Test Voltage Programmable: 40 to 1000V (10V increments), 1000 to 5100V (100V increments). Short Circuit Current: <1.6 mA ± 5%. DAR (1 min/30 sec): 0.02 to 50.00. Capacitance Measurement: 0.005 to 49.99 µF; Max resolution 1 nF. Leakage Current Measurement: 0.00 nA to 3 mA; Max resolution 1 pA. Discharge After Test: Yes, automatic. Discharge Voltage Display: Yes. Voltage Test/Safety Check: 0 to 1000 Vac/dc (16 to 420Hz); 1V Resolution. Voltage Warning Indicator: Yes >25V. Test Inhibition: Yes >25V.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC 6505. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your AEMC 6505 CALIBRATION and/or AEMC 6505 5000V Digital/Analog Megohmmeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: