AEMC 5070 CALIBRATION and AEMC 5070 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC 5070 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC 5070 (2130.30)   Description / Specification:    
AEMC 5070 5000V Graphical Megohmmeter / Insulation Tester

The AEMC 5070 5000V Graphical Megohmmeter is a fully automated graphical insulation resistance tester. Insulation Tester features selectable and programmable test voltage (40 to 5100V), programmable temperature correction of resistance readings and offers both a graphical plot of the test on the instrument and as a digital representation of results.The AEMC 5070 has an RS232 port to configure and run tests from a PC. Includes DataView graphing and analysis software. Specifications. Test Voltage: 500V (30 kohm to 2000 Gohm), 1000V (100 kohm to 4000 Gohm), 2500V (100 kohm to 10,000 Gohm), 5000V (300 kohm to 10,000 Gohm). User Selectable Test Voltage Programmable: 40 to 1000V (10V increments), 1000 to 5100V (100V increments). Accuracy 1 kohm / 40 Gohm: 5% of Reading ± 3 cts. Accuracy 40 Gohm to 10 Tohm: 15% of Reading ± 10 cts. Voltage Test/Safety Check: 0 to 1000 Vac/dc. Voltage Warning Indicator: yes >25 V. Smooth Function (user selectable) Digital filtering stabilizes display readings. Test Inhibition: Yes, adjustable from 25 to 1000V depending on test voltage range in use. Storage of Test Results: Stores over 1500 test results. Communication Port: RS-232.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC 5070. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your AEMC 5070 CALIBRATION and/or AEMC 5070 5000V Graphical Megohmmeter / Insulation Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: