AMPROBE AMB-3 CALIBRATION and AMPROBE AMB-3 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE AMB-3 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE AMB-3   Description / Specification:    
AMPROBE AMB-3 500V Handheld Analog Megohmmeter / Insulation Resistance

The Amprobe AMB-3 500V Analog Megohmmeter - Insulation Tester tests insulation of wires, cables, transformers and motors. It has automatic discharge of equipment capacitance for safe removal of test leads. Insulation resistance with 500 VDC test voltage: 0-1000 M-ohm, basic accuracy ± 10% Rdg @ (>10 M-ohm). Voltmeter: 0 to 600V AC. Voltmeter Accuracy: ± 1.5% Rdg + 3 LSD.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE AMB-3. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your AMPROBE AMB-3 CALIBRATION and/or AMPROBE AMB-3 500V Handheld Analog Megohmmeter / Insulation Resistance REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: