AMPROBE AMB-6D CALIBRATION and AMPROBE AMB-6D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE AMB-6D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE AMB-6D   Description / Specification:    
AMPROBE AMB-6D MEGATEST 1000 Digital Megohmmeter / Insulation Resistance

The Amprobe AMB-6D MEGATEST 1000 Digital Megohmmeter Insulation Resistance Tester tests insulation of wires, cables, transformers and motors. Features. Programmable timer to perform the Dielectric Absorption Ratio Test. Automatic voltmeter warns against hazardous energized systems. Internal memory to store measurements for future reference. Data download to PC. Insulation resistance with 50 VDC test voltage: 0.01 to 99.9 M-ohm, accuracy ± 2% Rdg + 2 LSD @ 0.01-49.9M-ohm. Insulation resistance with 100 VDC test voltage: 0.01 to 199.9 M-ohm, accuracy ± 2% Rdg + 2 LSD @ 0.01-99.9M-ohm. Insulation resistance with 250 VDC test voltage: 0.01 to 499 M-ohm, accuracy ± 2% Rdg + 2 LSD @ 0.01-249M-ohm. Insulation resistance with 500 VDC test voltage: 0.01 to 999 M-ohm, accuracy ± 2% Rdg + 2 LSD @ 0.01-499M-ohm. Insulation resistance with 1000 VDC test voltage: 0.01 to 1999 M-ohm, ± 2% Rdg + 2 LSD @ 0.01-999M-ohm. Low Resistance (without timer): 0.01 to 99.9 ohm, accuracy ± 2% Rdg + 2 LSD @ 0.01-99.9ohm. Low Resistance (with timer): 0.01 to 9.99 ohm, accuracy ± 2% Rdg + 2 LSD @ 0.01-9.9ohm. Optional, USB to RS-232 Adapter.



 

Standard Calibration $405.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE AMB-6D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your AMPROBE AMB-6D CALIBRATION and/or AMPROBE AMB-6D MEGATEST 1000 Digital Megohmmeter / Insulation Resistance REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: