AMPROBE AM-560 CALIBRATION and AMPROBE AM-560 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE AM-560 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   AMPROBE AM-560   Description / Specification:    
AMPROBE AM-560 Advanced HVAC Multimeter

The Amprobe AM-560 Advanced HVAC Multimeter is specifically designed for the more demanding HVAC applications. The AM-560 measures a complete range of electrical parameters and key functions such as dual thermocouples for taking differential temperature measurements, low pass filter to take accurate measurements on variable frequency drives and capacitance to check motor startup capacitors. It also features micro amps for flame sensor troubleshooting, and a complete range of electrical parameters. With built-in flashlight and VolTect ™ non-contact voltage detection. Specifications. AC Voltage Ranges: 6.000 / 60.00 / 600.0 / 1000 V. AC Voltage Best Accuracy: ±(1.0% Rdg + 3 LSD) @ 45 Hz to 400 Hz, 0 V to 600 V. DC Voltage Ranges: 600.0 mV / 6.000 / 60.00 / 600.0 / 1000 V. DC Voltage Best Accuracy: ±(0.5% Rdg + 2 LSD) @ 6 V to 600 V ranges. Resistance Ranges: 600.0 Ohms / 6.000 / 60.00 / 600.0 kOhms / 6.000 / 60.00 MOhms. Resistance Best Accuracy: ±(1.0% Rdg + 2 LSD) @ 6 kOhms to 600 kOhms ranges. AC Current Ranges: 600.0 µA / 6000 µA / 60.00 mA / 500.0 mA / 10.00 A. AC Current Best Accuracy: ±(1.2% Rdg + 5 LSD) @ 600 µA to 6000 µA ranges, 45 Hz to 400 Hz. DC Current Ranges: 600.0 µA / 6000 µA / 60.00 mA / 500.0 mA / 10.00 A. DC Current Best Accuracy: ±(1.0% Rdg + 2 LSD) @ 600 µA to 6000 µA ranges. Frequency Ranges: 60.00 / 600.0 Hz / 6.000 / 60.00 / 600.0 kHz / 6.000 / 60.00 MHz. Frequency Best Accuracy: ±(0.1% Rdg + 3 LSD). Capacitance Ranges: 60.00 / 600.0 nF / 6.000 / 60.00 / 600.0 / 6000 µF / 60.00 mF. Capacitance Best Accuracy: ±(3.0% Rdg + 5 LSD) @ 600 nF to 60 µF ranges. Duty Cycle: 10.00% to 90.00%. Duty Cycle Best Accuracy: ±(1.2% Rdg + 30 LSD) @ 5Hz to 2 kHz. Temperature Ranges: -40 °F to 1832 °F / -40 °C to 1000 °C. Temperature Best Accuracy: °F: ±(1.0% rdg + 12) @ >104 °F to 752 °F / °C: ±(1.0% rdg + 8) @ >40 °C to 400 °C. Safety rated: CAT IV 600V, CAT III 1000V. Dual reading backlit LCD display with analog bar graph.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE AM-560. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your AMPROBE AM-560 CALIBRATION and/or AMPROBE AM-560 Advanced HVAC Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: