AMPROBE AM-530 CALIBRATION and AMPROBE AM-530 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE AM-530 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   AMPROBE AM-530   Description / Specification:   Spec Sheet 
AMPROBE AM-530 True-rms Electrical Contractor Multimeter

The Amprobe AM-530 True-rms Electrical Contractor Multimeter is the fully-featured multimeter of choice for the professional electrical contractor. Measure and verify presence of voltage in order to connect equipment or to perform repairs, run new wiring, check continuity of electrical connections, identify blown fuses, troubleshoot motors or check transformers. The AM-530 is true-rms sensing to accurately measure voltage on systems affected by harmonics as well as a built-in flashlight to detect wire colors in the dark, a “third hand probe holder and VolTect ™ non-contact voltage detection. Specifications. AC Voltage Ranges: 400 mV / 4.000 / 40.00 / 400.0 / 600 V. AC Voltage Best Accuracy: ±(1.0% Rdg + 3 LSD) @ 45 Hz to 400 Hz, 4 V to 400V ranges. DC Voltage Ranges: 400 mV / 4.000 / 40.00 / 400.0 / 600 V. DC Voltage Best Accuracy: ±(0.8% Rdg + 1 LSD) @ 4 V to 400 V ranges. Resistance Ranges: 400.0 Ohms / 4.000 / 40.00 / 400.0 kOhms / 4.000 / 40.00 MOhms. Resistance Best Accuracy: ±(1.0% Rdg + 2 LSD) @ 4 kOhms to 400 kOhms ranges. AC Current Ranges: 400.0 / 4000 µA / 40.00 / 400.0 mA / 4.000 / 10.00 A. AC Current Best Accuracy: ±(1.2% Rdg + 3 LSD) @ 400 µA to 400 mA ranges, 45 Hz to 400 Hz. DC Current Ranges: 400.0 / 4000 µA / 40.00 / 400.0 mA / 4.000 / 10.00 A. DC Current Best Accuracy: ±(1.0% Rdg + 2 LSD) @ 400 µA to 400 mA ranges. Frequency Range: 10 Hz to 10 MHz. Frequency Best Accuracy: ±(0.1% Rdg + 4 LSD). Capacitance Ranges: 40.00 / 400.0 nF / 4.000 / 40.00 / 400.0 / 4000 µF. Capacitance Best Accuracy: ±(3.0% Rdg + 5 LSD) @ 400 nF to 40 µF ranges. Temperature Ranges: -40 °F to 1832 °F / -40 °C to 1000 °C. Temperature Best Accuracy: °F: ±(1.8% rdg + 6 °F) @ >32 °F to 212 °F / °C: ±(1.2% rdg + 3 °C) @ >0 °C to 100 °C. Built-in flashlight and back lit LCD display with analog bar graph. Safety rated: CAT III 600V.



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE AM-530. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your AMPROBE AM-530 CALIBRATION and/or AMPROBE AM-530 True-rms Electrical Contractor Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: