AMPROBE AM-530 CALIBRATION and AMPROBE AM-530 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE AM-530 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   AMPROBE AM-530   Description / Specification:   Spec Sheet 
AMPROBE AM-530 True-rms Electrical Contractor Multimeter

The Amprobe AM-530 True-rms Electrical Contractor Multimeter is the fully-featured multimeter of choice for the professional electrical contractor. Measure and verify presence of voltage in order to connect equipment or to perform repairs, run new wiring, check continuity of electrical connections, identify blown fuses, troubleshoot motors or check transformers. The AM-530 is true-rms sensing to accurately measure voltage on systems affected by harmonics as well as a built-in flashlight to detect wire colors in the dark, a “third hand probe holder and VolTect ™ non-contact voltage detection. Specifications. AC Voltage Ranges: 400 mV / 4.000 / 40.00 / 400.0 / 600 V. AC Voltage Best Accuracy: ±(1.0% Rdg + 3 LSD) @ 45 Hz to 400 Hz, 4 V to 400V ranges. DC Voltage Ranges: 400 mV / 4.000 / 40.00 / 400.0 / 600 V. DC Voltage Best Accuracy: ±(0.8% Rdg + 1 LSD) @ 4 V to 400 V ranges. Resistance Ranges: 400.0 Ohms / 4.000 / 40.00 / 400.0 kOhms / 4.000 / 40.00 MOhms. Resistance Best Accuracy: ±(1.0% Rdg + 2 LSD) @ 4 kOhms to 400 kOhms ranges. AC Current Ranges: 400.0 / 4000 µA / 40.00 / 400.0 mA / 4.000 / 10.00 A. AC Current Best Accuracy: ±(1.2% Rdg + 3 LSD) @ 400 µA to 400 mA ranges, 45 Hz to 400 Hz. DC Current Ranges: 400.0 / 4000 µA / 40.00 / 400.0 mA / 4.000 / 10.00 A. DC Current Best Accuracy: ±(1.0% Rdg + 2 LSD) @ 400 µA to 400 mA ranges. Frequency Range: 10 Hz to 10 MHz. Frequency Best Accuracy: ±(0.1% Rdg + 4 LSD). Capacitance Ranges: 40.00 / 400.0 nF / 4.000 / 40.00 / 400.0 / 4000 µF. Capacitance Best Accuracy: ±(3.0% Rdg + 5 LSD) @ 400 nF to 40 µF ranges. Temperature Ranges: -40 °F to 1832 °F / -40 °C to 1000 °C. Temperature Best Accuracy: °F: ±(1.8% rdg + 6 °F) @ >32 °F to 212 °F / °C: ±(1.2% rdg + 3 °C) @ >0 °C to 100 °C. Built-in flashlight and back lit LCD display with analog bar graph. Safety rated: CAT III 600V.



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE AM-530. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your AMPROBE AM-530 CALIBRATION and/or AMPROBE AM-530 True-rms Electrical Contractor Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: