SLAUGHTER 2965 CALIBRATION and SLAUGHTER 2965 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SLAUGHTER 2965 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   SLAUGHTER 2965   Description / Specification:   Spec Sheet 
SLAUGHTER 2965 5kV AC, 6kV DC Hipot with Ground Continuity Check

The Slaughter 2965 is designed to simplify every aspect of safety testing for operators of all comfort levels. With multiple memories and an optional RS-232 interface, you can quickly perform tests on a variety of DUT’s from the front panel or with a PC. Use this in stand-alone applications or interconnect with a 2600 series tester to form a complete test system for NRTL compliance.

Specifications

Dielectric Withstand Test Mode
Output
Rating AC: 0 - 5000 V, 2 V/step, 12 mA
Rating DC: 0 - 6000 V, 2 V/step, 5 mA
Voltage : ± (1% of output + 5 V)

Voltage Setting
Range: 0 V - max output rating, 10 V/step
Resolution: 0.01 kV
Accuracy: ± (2% of setting + 5 V) relative to displayed output, can be adjusted during operation via UP and DOWN arrow keys

AC Output
Frequency: 50/60 Hz user selectable
AC Wave Form: Sine wave
AC Wave Form Distortion: <2% THD

AC Mode Failure Settings
High Limit: 0.10 - 12.00 mA, 0.01 mA/step
Low Limit: 0.00, 0.10 - 12.00 mA, 0.01 mA/step (0=OFF)
Accuracy: ± (2% of setting + 0.02 mA)

DC Mode Failure Settings
High Limit: 0.02 - 5.00 mA, 0.01 mA/step
Low Limit: 0.00, 0.02 - 5.00 mA, 0.01mA/step (0=OFF)
Accuracy: ± (2% of setting + 0.02 mA)

Discharge Time: ≤ 200 ms

Ground Continuity Check
Current: DC 0.1 A ± 0.01 A, fixed
High Limit: 0.00-1.50 Ω
Low Limit: 0.01-1.50 Ω
Offset: 0.00-0.50 Ω
Resolution: 0.01 Ω
Accuracy: ± (2% of setting + 0.02 Ω)



 

Standard Calibration $330.00 *
*This is a Web introductory price for one calibration of the SLAUGHTER 2965. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your SLAUGHTER 2965 CALIBRATION and/or SLAUGHTER 2965 5kV AC, 6kV DC Hipot with Ground Continuity Check REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: