The Slaughter 2965 is designed to simplify every aspect of safety testing for operators of all comfort levels. With multiple memories and an optional RS-232 interface, you can quickly perform tests on a variety of DUT’s from the front panel or with a PC. Use this in stand-alone applications or interconnect with a 2600 series tester to form a complete test system for NRTL compliance.
Specifications
Dielectric Withstand Test Mode Output Rating AC: 0 - 5000 V, 2 V/step, 12 mA Rating DC: 0 - 6000 V, 2 V/step, 5 mA Voltage : ± (1% of output + 5 V)
Voltage Setting Range: 0 V - max output rating, 10 V/step Resolution: 0.01 kV Accuracy: ± (2% of setting + 5 V) relative to displayed output, can be adjusted during operation via UP and DOWN arrow keys
AC Output Frequency: 50/60 Hz user selectable AC Wave Form: Sine wave AC Wave Form Distortion: <2% THD
AC Mode Failure Settings High Limit: 0.10 - 12.00 mA, 0.01 mA/step Low Limit: 0.00, 0.10 - 12.00 mA, 0.01 mA/step (0=OFF) Accuracy: ± (2% of setting + 0.02 mA)
DC Mode Failure Settings High Limit: 0.02 - 5.00 mA, 0.01 mA/step Low Limit: 0.00, 0.02 - 5.00 mA, 0.01mA/step (0=OFF) Accuracy: ± (2% of setting + 0.02 mA)
Discharge Time: ≤ 200 ms
Ground Continuity Check Current: DC 0.1 A ± 0.01 A, fixed High Limit: 0.00-1.50 Ω Low Limit: 0.01-1.50 Ω Offset: 0.00-0.50 Ω Resolution: 0.01 Ω Accuracy: ± (2% of setting + 0.02 Ω)
|