AMPROBE AC68C CALIBRATION and AMPROBE AC68C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE AC68C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE AC68C   Description / Specification:   Spec Sheet 
AMPROBE AC68C 600 Amp TRMS Clamp Type Digital Multimeter

The Amprobe AC68C True-rms 600A Clamp Meter measures non-linear load current with true-rms readings. Specifications. DC Voltage Ranges: 600 V. DC Voltage Accuracy: ± (0.75 % rdg + 2 dgts). DC Voltage Resolution: 1 V in 600 V range. AC Voltage (40-450 Hz) Ranges: 400 V, 600 V. AC Voltage Accuracy: ± (1.2 % rdg + 5 dgts). AC Voltage Resolution: 0.1 V in 400 V range. DC Current Ranges: 400 A, 600 A. DC Current Accuracy: ± (2 % rdg + 5 dgts). DC Current Resolution: 0.1 A in 400 A range. AC Current (40-450 Hz) Ranges: 400 A, 600 A. AC Current Accuracy: ± (2 % rdg + 5 dgts). AC Current Resolution: 0.1 A in 400 A range. Frequency (Hz), Current and Voltage Ranges: 4 kHz, 20 kHz. Frequency (Hz) Accuracy: ± (0.5 % rdg + 5 dgts). Frequency (Hz) Resolution: 1 Hz in 4 kHz range. Resistance Range: 4 kohm. Resistance Accuracy: ± ( 1.0 % rdg + 5 dgts). Resistance Resolution: 1 ohm in 4 kohm range. Diode Test Accuracy: ± (1.0 % rdg + 2 dgts). Diode Test Resolution: 0.001 V. Continuity Range Threshold: Tone at 40 ohm ± 15 ohm. Peak Hold Measurement AC Voltage (40-450 Hz) Ranges: 400 V, 600 V. Peak Hold Measurement AC Voltage Accuracy: ± (1.5 % rdg + 10 dgts). AC Voltage Resolution: 0.1 V in 400 V range. Peak Hold Measurement AC Current (40-450 Hz) Ranges: 400 A, 600 A. Peak Hold Measurement AC Current Accuracy: ± (2 % rdg + 10 dgts). AC Current Resolution: 0.1 A in 400 A range. Overload Protection Voltage: 1000 V DC / 750 V AC. Overload Protection Current: 800 Amps. Display: 3-3/4 digit, LCD, max reading of 3999.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE AC68C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your AMPROBE AC68C CALIBRATION and/or AMPROBE AC68C 600 Amp TRMS Clamp Type Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: