AMPROBE ACDC-400 CALIBRATION and AMPROBE ACDC-400 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACDC-400 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACDC-400   Description / Specification:   Spec Sheet 
AMPROBE ACDC-400 400 Amp Digital AC/DC Clamp-on Multimeter

The Amprobe ACDC-400 Clamp Meter is full featured with wide measurement capabilities. It measures both AC and DC current to 400 amps, AC and DC voltage to 600V, plus resistance and continuity. The ACDC-400 also offers software features of min/max and relative measurements with a large digital and analog display and backlight. Specifications. DC Voltage Range: 400.0 mV 4.000V, 40.00V, 400.0V (Accuracy ± (0.8% rdg + 2 dgts)), 600V (Accuracy ± (1.0% rdg + 2 dgts)). AC Voltage (sinusoidal), 40Hz to 60Hz Range: 400.0 mV (Accuracy ± (1.0% rdg + 50 dgts)). AC Voltage (sinusoidal), 50Hz to 500Hz Range: 4.000V, 40.00V, 400.0V (Accuracy ± (1.0% rdg + 3 dgts)), 600V (Accuracy ± (1.2% rdg + 3 dgts)). DC Current (Clamp-On) Range: 0.00A to 40.00A (Accuracy ± (2.0% rdg + 10 dgts)), 40.0A to 400.0A (Accuracy ± (2.0% rdg + 10 dgts)). AC Current (Clamp-On) 50Hz to 60Hz Range: 0.00A to 40.00A (Accuracy ± (2.0% rdg + 10 dgts)), 40.0A to 400.0A (Accuracy ± (2.0% rdg + 10 dgts)). Resistance Range: 400.0 ohm (Accuracy ± (1.0% rdg + 5 dgts)), 4.000 kohm, 40.00 kohm, 400.0 kohm, 4.000 Mohm (Accuracy ± (1.0% rdg + 3 dgts)), 40.00 Mohm (Accuracy ± (3.0% rdg + 3 dgts)). Open Circuit Voltage: 0.45 Vdc typical; 1.5 Vdc typical for 400.0 ohm. Continuity Tester Open Circuit Voltage: 1.4Vdc typical, Audible threshold: < 40 ohm. Display 3-3/4 digits 4000 counts LCD display.



 

Standard Calibration $255.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE ACDC-400. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your AMPROBE ACDC-400 CALIBRATION and/or AMPROBE ACDC-400 400 Amp Digital AC/DC Clamp-on Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: