AMPROBE 34XR-A CALIBRATION and AMPROBE 34XR-A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE 34XR-A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   AMPROBE 34XR-A   Description / Specification:   Spec Sheet 
AMPROBE 34XR-A True-rms Digital Multimeter with Temperature

The Amprobe 34XR-A Digital Multimeter, a true-rms digital multimeter with temperature and backlight for contractors and field service technicians. Specifications. DC Voltage ranges: 400 mV, 4 V, 40 V, 400 V, 1000 V. DC Voltage accuracy: ± (0.5 % rdg + 1 dgt). DC Voltage resolution: 100 µV. AC Voltage (45 Hz to 2.5 kHz) ranges: 400 mV, 4 V, 40 V, 400 V, 750 V. AC Voltage accuracy: 400 mV range 45 to 100 Hz ± (1.2 % rdg + 8 dgts), 750 V range 45 to 1 kHz ± (2.0 % rdg + 8 dgts), All other ranges 45 to 500 Hz ± (1.2 % rdg + 8 dgts), All other ranges 500 to 2 kHz ± (1.2 % rdg + 8 dgts). AC Voltage (45 Hz to 2 kHz) resolution: 100 µV. DC Current ranges: 400 µA, 4 mA, 40 mA, 300 mA, 10 A. DC Current accuracy: 400 µA to 300 mA ranges ± (1.0 % rdg + 1 dgt), 10 A range: ± (2.0 % rdg + 3 dgts). DC Current resolution: 0.1 µA. AC Current (45 Hz to 1 kHz) ranges: 400 µA, 4 mA, 40 mA, 300 mA, 10 A. AC Current (45 Hz to 1 kHz) accuracy: 400 µA to 300 mA ranges ± (1.5 % rdg + 8 dgts), 10A range: ± (2.5 % rdg + 10 dgts). AC Current resolution: 0.1 µA. Resistance Ranges: 400 ohm, 4 kohm, 40 kohm, 400 kohm, 4 Mohm, 40 Mohm. Resistance Accuracy: 400 ohm to 4 Mohm ranges ± (1.0 % rdg + 4 dgts), 40 Mohm range ± (2.0 % rdg + 5 dgts). Resistance Resolution: 100 mohm. Capacitance Ranges: 4 µF, 40 µF, 400 µF, 4000 µF. Capacitance Accuracy: 4 µF range ± (5.0 % rdg + 10 dgts), 40 µF, 400 µF ranges ± (5.0 % rdg + 5 dgts), 4000 µF range ± (5.0 % rdg + 15 dgts). Capacitance Resolution: 0.1 µF. Temperature Ranges: -20 °C to 1000 °C, -4 °F to 1832 °F. Frequency (autoranging) Ranges: 4 kHz, 40 kHz, 400 kHz, 1 MHz. Frequency Accuracy: ± (0.1 % rdg + 3 dgts). Frequency Resolution: 1 Hz. Duty Cycle Ranges: 0 to 90 %. Continuity Audible Indication: < 35 ohm. Diode Test Current: 1.0 mA (approximate). Overload Protection AC/DC Voltage: All ranges 1000 V DC or 750 V AC RMS. Display: 3-3/4 digit LCD, 3999 counts with 41-segment analog bar graph. Display Update Rate: 2/sec, nominal.



 

Standard Calibration $110.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE 34XR-A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your AMPROBE 34XR-A CALIBRATION and/or AMPROBE 34XR-A True-rms Digital Multimeter with Temperature REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: