AMPROBE ACD-41PQ CALIBRATION and AMPROBE ACD-41PQ REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE ACD-41PQ Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AMPROBE ACD-41PQ   Description / Specification:   Spec Sheet 
AMPROBE ACD-41PQ 1000 Amp Power Quality Clamp Meter with THD Measurement

The Amprobe ACD-41PQ Power Quality Clamp Meter with THD Measurement provides a simple and effective way to verify if the electrical system is affected by harmonics (Total Harmonic Distortion to 51st harmonic). Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit. TRMS sensing. Specifications. AC Current: 40.0 / 400.0 / 1000 A. AC Current Basic Accuracy: +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz. DC Voltage: 600.0V. DC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD). AC Voltage: 600.0V. AC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz. Resistance: 999.9 ohm. Resistance Basic Accuracy: +/-(1.0% Rdg + 6 LSD). Frequency: 5.00 Hz to 500.0 Hz. Frequency Basic Accuracy: +/-(0.5% Rdg +4 LSD). THD-F: 0.0% to 99.9%. THD-F Basic Accuracy: 1.5% of Reading + 6d @ Fundamental Frequency. Active Power (W): 0 to 600.0 kW. Active Power (W) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics fundamental to 10th & PF > 0.7. Reactive Power (VAR): 0 to 600.0 kVAR. Reactive Power (VAR) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics fundamental to 10th & PF > 0.7. Apparent Power (VA): 0 to 600.0 kVA. Apparent Power (VA) Basic Accuracy: +/-(2.0% Rdg + 6 LSD) @ Harmonics fundamental to 10th. Power Factor: 0.10 to 0.99. Power Factor Basic Accuracy: +/- 3 LSD @ Harmonics Fund to 21th. Temperature: -58°F to 572° F (-50° C to 300° C). Temperature Basic Accuracy: +/-(2.0% Rdg + 6°F) +/-(2.0 % Rdg + 3°C).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE ACD-41PQ. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your AMPROBE ACD-41PQ CALIBRATION and/or AMPROBE ACD-41PQ 1000 Amp Power Quality Clamp Meter with THD Measurement REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: