EXTECH INSTRUMENTS EX820 CALIBRATION and EXTECH INSTRUMENTS EX820 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX820 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   EXTECH INSTRUMENTS EX820   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS EX820 1000 Amp AC True RMS Clamp/DMM+IR Thermometer

The Extech EX820 1000 Amp True RMS AC Clamp Meter with IR Thermometer multimeter functions include, AC/DC Voltage and Current, Resistance, Capacitance, Frequency, Diode, Continuity and Type K Thermometer. Features include Data Hold and Min/Max. Autoranging with manual range button. Peak hold captures inrush currents and Transients. 4000 count backlit display. Specifications. AC Current: 0.1 to 1000A. AC Current Basic Accuracy: ±2.5%. AC Voltage: 0.1mV to 600V. AC Voltage Basic Accuracy: ±1.5%. DC Voltage: 0.1mV to 600V. DC Voltage Basic Accuracy: ±1.5%. Resistance: 0.1 to 40 Mohm. Resistance Basic Accuracy: ±1.5%. Capacitance: 0.001nF to 40,000µF. Capacitance Basic Accuracy: ±3.0%. Frequency: 0.001 kHz to 4 kHz. Frequency Basic Accuracy: ±1.5%. Type K Temperature: -4 to 1400°F,-20 to 760°C. Type K Temperature Basic Accuracy: ±(3%rdg+9°F/5°C). IR Temperature (IR): -58 to 518°F, -50 to 270°C. IR Temperature (IR)Basic Accuracy: ±2.0% rdg or ±4°F/±2°C.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX820. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your EXTECH INSTRUMENTS EX820 CALIBRATION and/or EXTECH INSTRUMENTS EX820 1000 Amp AC True RMS Clamp/DMM+IR Thermometer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: