EXTECH INSTRUMENTS MP530A CALIBRATION and EXTECH INSTRUMENTS MP530A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS MP530A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS MP530A   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS MP530A MultiPro True RMS Professional MultiMeter & Temp

The Extech MP530A MultiPro True RMS Professional MultiMeter with RS-232 & Temp features a backlit 5000 count LCD display for high resolution. Smart auto power off is disabled if signal is present at test leads. Measurement functions include AC/DC Voltage and Current, Resistance, Frequency, Capacitance, Diode and Continuity. Specifications. AC Voltage Ranges: 50mV, 500mV, 5V, 50V, 500V, 1000V. AC Voltage Maximum Resolution: 0.01 mV. AC Voltage Basic Accuracy (%rdg+digits): ±(0.8%+3d). DC Voltage Ranges: 50mV, 500mV, 5V, 50V, 500V, 1000V. DC Voltage Maximum Resolution: 0.01 mV. DC Voltage Basic Accuracy (%rdg+digits): ±(0.08%+2d). AC Current Ranges: 500µA, 5000µA, 50mA, 500mA, 5A, 10A. AC Current Maximum Resolution: 0.1 µA. AC Current Basic Accuracy (%rdg+digits): ±(0.8% + 4d). DC Current Ranges: 500µA, 5000µA, 50mA, 500mA, 5A, 10A. DC Current Maximum Resolution: 0.1 µA. DC Current Basic Accuracy (%rdg+digits): ±(0.2% + 4d). Resistance Ranges: 50, 500, 5k, 50k, 500k, 5M, 50Mohm. Resistance Maximum Resolution: 0.01 ohm. Resistance Basic Accuracy (%rdg+digits): ±(0.1% + 2d). Capacitance Ranges: 50 nF ,500 nF, 5 µF, 50 µF, 500 µF, 9999 µF. Capacitance Maximum Resolution: 0.01 nF. Capacitance Basic Accuracy (%rdg+digits): ±(0.8% + 3d). Frequency Ranges: 5 Hz to 125 kHz. Frequency Maximum Resolution: 0.001 Hz. Frequency Basic Accuracy (%rdg+digits): ±(0.01%+2d). Temperature Ranges: -58 to 1832°F (-50 to 1000°C ). Temperature Maximum Resolution: 1°F/°C. Temperature Basic Accuracy (%rdg+digits): ±(0.3%+3d). Diode Test: Typical test current; 0.4mA, open circuit voltage; <3.5VDC. Digital Display: 5000-count LCD display; 5 per second nominal refresh rate. Bar Graph Display: 52-segment bargraph; 60 per second nominal refresh rate.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS MP530A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your EXTECH INSTRUMENTS MP530A CALIBRATION and/or EXTECH INSTRUMENTS MP530A MultiPro True RMS Professional MultiMeter & Temp REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.