EXTECH INSTRUMENTS EX520 CALIBRATION and EXTECH INSTRUMENTS EX520 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX520 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX520   Description / Specification:   Spec Sheet 
EXTECH INSTRUMENTS EX520 True RMS Industrial MultiMeter

The Extech EX520 Heavy Duty True RMS Industrial MultiMeter has a 6,000 count large LCD display, temperature function and waterproof housing. AC/DC Voltage & Current, Resistance, Capacitance, Frequency, Temperature, Duty Cycle, Diode/Continuity. Dual sensitivity frequency functions (electrical/electronic). Specifications. DC Voltage Ranges: 600mV, 6V, 60V, 600V, 1000V. DC Voltage Maximum Resolution: 0.1 mV. DC Voltage Accuracy: ± (0.09% reading + 2 digits). AC Voltage Ranges: 6V, 60V, 600V, 1000V. AC Voltage Maximum Resolution: 0.001 V. AC Voltage Accuracy: ±(1.0% reading + 3 dgts) @ 50 to 60Hz, ±(2.0% reading + 3 dgts) @ 40Hz to 1KHz. DC Current Ranges: 600µA, 6000µA, 60mA, 600mA, 6A, 10A. DC Current Maximum Resolution: 0.1 µA. DC Current Accuracy: ±(1.0% + 3d). AC Current Ranges: 600µA, 6000µA, 60mA, 600mA, 6A, 10A. AC Current Maximum Resolution: 0.1 µA. AC Current Accuracy: ±(1.5% + 3d) @ 40Hz to 1kHz. Resistance Ranges: 600, 6k, 60k, 600k, 6M, 40Mohm. Resistance Maximum Resolution: 0.1 ohm. Resistance Accuracy: 600, 6k, 60k, 600k, 6Mohm ± (0.3% reading + 4 digits), 40Mohm ± (0.3% reading + 20 digits). Capacitance Ranges: 60 nF, 600 nF, 6 µF, 60 µF, 600 µF, 1000µF. Capacitance Maximum Resolution: 0.01 nF. Capacitance Accuracy: 60 nF, 600 nF, 6 µF, 60 µF, 600 µF ±(3.5% reading + 4 digits), 1000µF ±(5% reading + 5 digits). Frequency (electronic): 0.001Hz to 40 MHz. Frequency (electronic) Accuracy: ±(0.1% reading + 1 digits). Frequency (electrical): 10Hz to 400Hz. Frequency (electrical) Accuracy: ±(0.5% reading). Duty Cycle: 0.1% to 99.9%. Duty Cycle Maximum Resolution: 0.1%. Duty Cycle Accuracy: ±(1.2% reading + 2 digits). Temperature Ranges: -4 to 1382°F (-20 to 750°C ). Temperature Maximum Resolution: 0.1°F/°C. Temperature Accuracy: ±(3.0% reading + 5°C /9°F) (probe accuracy not included). Diode Test: Test current of 0.9mA typical, open circuit voltage 2.8V DC typical. Continuity Check: Audible signal will sound if the resistance is less than 100 ohm (approx.), test current <0.35 mA. Display: 6,000 count backlit liquid crystal with bargraph.



 

Standard Calibration $75.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the EXTECH INSTRUMENTS EX520. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your EXTECH INSTRUMENTS EX520 CALIBRATION and/or EXTECH INSTRUMENTS EX520 True RMS Industrial MultiMeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: