AEMC H110 CALIBRATION and AEMC H110 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC H110 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC H110 (2117.81)   Description / Specification:   Spec Sheet 
AEMC H110 5KV AC Withstanding Voltage Tester

The AEMC H110 AC Hi-Pot is designed for Withstanding Voltage testing, providing a safe and accurate test environment for the operator. It complies with the requirement of the electrical equipment and appliance testing standard, UL, CSA and other international standards. The AEMC H110 can be used for withstanding voltage tests of the various types of electrical equipment and components. Specifications. AC Voltage Range: 100V to 5000V (5 kV). Voltage Step: 5V/step. Voltage Regulation: 1% of reading + 5 counts. Voltage Accuracy: 1% of reading + 5 counts (above 500V). Max Current: 20 mA @5 kVAC. Current Limit: 0.10 to 20 mA, 0.01 mA/step. Current Accuracy: 1% of reading + 5 counts. Continuity Check Test Current: 100mA (01A). Current Accuracy: ± 10%. Detect Accuracy: 0 1 ohm @ 1 ohm. ARC Detect Current: 1 to 20 mA (1mA step). Storage: 6 tests; 6 steps per test. Remote Interface Type of Terminal: 9-pin D-sub connector.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC H110. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your AEMC H110 CALIBRATION and/or AEMC H110 5KV AC Withstanding Voltage Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: