AEMC H210 CALIBRATION and AEMC H210 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC H210 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC H210 (2117.83)   Description / Specification:   Spec Sheet 
AEMC H210 5KV AC, 6KV DC Withstanding Voltage Tester

The AEMC H210 AC/DC Hi-Pot is designed for Withstanding Voltage testing, providing a safe and accurate test environment for the operator. It complies with the requirement of the electrical equipment and appliance testing standard, UL, CSA and other international standards. The AEMC H210 can be used for withstanding voltage tests of the various types of electrical equipment and components. Specifications. AC Voltage Range: 100V to 5000V (5 kV). Voltage Step: 5V/step. Voltage Regulation: 1% of reading + 5 counts. Voltage Accuracy: 1% of reading + 5 counts (above 500V). Max Current: 20 mA @5 kVAC. Current Limit: 0.10 to 20 mA, 0.01 mA/step. Current Accuracy: 1% of reading + 5 counts. DC Voltage Range: 100V to 6000V (6 kV). Voltage Step: 5V/step. Voltage Regulation: 1% of reading + 5 counts. Voltage Accuracy: 1% of reading + 5 counts (above 500V). Max Current: 7.5 mA @6 kVAC. Current Limit: 0.10 to 7.5 mA, 0.01 mA/step. Current Accuracy: 1% of reading + 5 counts. Continuity Check Test Current: 100mA (01A). Current Accuracy: ± 10%. Detect Accuracy: 0 1 ohm @ 1 ohm. ARC Detect Current: 1 to 20 mA (1mA step). Storage: 6 tests; 6 steps per test. Remote Interface Type of Terminal: 9-pin D-sub connector.



 

Standard Calibration $275.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC H210. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your AEMC H210 CALIBRATION and/or AEMC H210 5KV AC, 6KV DC Withstanding Voltage Tester REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: