AEMC H210 CALIBRATION and AEMC H210 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC H210 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC H210 (2117.83)   Description / Specification:   Spec Sheet 
AEMC H210 5KV AC, 6KV DC Withstanding Voltage Tester

The AEMC H210 AC/DC Hi-Pot is designed for Withstanding Voltage testing, providing a safe and accurate test environment for the operator. It complies with the requirement of the electrical equipment and appliance testing standard, UL, CSA and other international standards. The AEMC H210 can be used for withstanding voltage tests of the various types of electrical equipment and components. Specifications. AC Voltage Range: 100V to 5000V (5 kV). Voltage Step: 5V/step. Voltage Regulation: 1% of reading + 5 counts. Voltage Accuracy: 1% of reading + 5 counts (above 500V). Max Current: 20 mA @5 kVAC. Current Limit: 0.10 to 20 mA, 0.01 mA/step. Current Accuracy: 1% of reading + 5 counts. DC Voltage Range: 100V to 6000V (6 kV). Voltage Step: 5V/step. Voltage Regulation: 1% of reading + 5 counts. Voltage Accuracy: 1% of reading + 5 counts (above 500V). Max Current: 7.5 mA @6 kVAC. Current Limit: 0.10 to 7.5 mA, 0.01 mA/step. Current Accuracy: 1% of reading + 5 counts. Continuity Check Test Current: 100mA (01A). Current Accuracy: ± 10%. Detect Accuracy: 0 1 ohm @ 1 ohm. ARC Detect Current: 1 to 20 mA (1mA step). Storage: 6 tests; 6 steps per test. Remote Interface Type of Terminal: 9-pin D-sub connector.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC H210. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your AEMC H210 CALIBRATION and/or AEMC H210 5KV AC, 6KV DC Withstanding Voltage Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: