AEMC H115 CALIBRATION and AEMC H115 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AEMC H115 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   AEMC H115 (2117.82)   Description / Specification:   Spec Sheet 
AEMC H115 5KV AC Withstanding Voltage / IR Tester

The AEMC H115 AC Hi-Pot with Insulation Resistance testing is designed for Withstanding Voltage testing, providing a safe and accurate test environment for the operator. It complies with the requirement of the electrical equipment and appliance testing standard, UL, CSA and other international standards. The AEMC H115 can be used for withstanding voltage tests of the various types of electrical equipment and components. Specifications. AC Voltage Range: 100V to 5000V (5 kV). Voltage Step: 5V/step. Voltage Regulation: 1% of reading + 5 counts. Voltage Accuracy: 1% of reading + 5 counts (above 500V). Max Current: 20 mA @5 kVAC. Current Limit: 0.10 to 20 mA, 0.01 mA/step. Current Accuracy: 1% of reading + 5 counts. Insulation Resistance (IR) DC Voltage: 500V or 1000V. IR Resistance Range: 1 to 9,999 M-ohm. IR Resistance Accuracy: 1 to 500 M-ohm (5% of reading), 501 to 2000 M-ohm (10% of reading). Continuity Check Test Current: 100mA (01A). Current Accuracy: ± 10%. Detect Accuracy: 0 1 ohm @ 1 ohm. ARC Detect Current: 1 to 20 mA (1mA step). Storage: 6 tests; 6 steps per test. Remote Interface Type of Terminal: 9-pin D-sub connector.



 

Standard Calibration $295.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AEMC H115. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your AEMC H115 CALIBRATION and/or AEMC H115 5KV AC Withstanding Voltage / IR Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: