ROHDE & SCHWARZ SMA100A CALIBRATION and ROHDE & SCHWARZ SMA100A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ SMA100A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   ROHDE & SCHWARZ SMA100A (1400.0000.02)   Description / Specification:   Spec Sheet 
ROHDE & SCHWARZ SMA100A 3 GHz Signal Generator

The R&S SMA 100A 3 GHz Signal Generator features very low SSB phase noise of typ. -135 dBc (20 kHz carrier offset, f = 1 GHz, 1 Hz measurement bandwidth), typ. -140 dBc with the Enhanced Phase Noise Performance option (R&S SMA-B22). Wideband noise of typ. -160 dBc (>10 MHz carrier offset, f = 1 GHz, 1 Hz measurement bandwidth). Nonharmonics of typ. -100 dBc (>10 kHz carrier offset, f < 1500 MHz, with the R&S SMA-B22 option). High-stability reference oscillator as standard. Very low phase noise at low frequencies due to internal division of the fundamental frequency range (750 MHz to 1500 MHz) down to 6.6 MHz. Ideal for use in production with very short frequency and level setting times of <3 ms across the entire frequency and level range, <450 µs in the list mode. Frequency setting time of typ. <10 µs within a bandwidth of 40 MHz due to direct access to the DDS-based synthesizer (with the R&S SMA-B20 or -B22 option). AM, broadband FM/phaseM (R&S SMA-B20 or -B22), pulse modulation. Remote control via GPIB or LAN.
Specifications.

Frequency Range: 9 kHz to 3 GHz.
Resolution of setting: 0.01 Hz.
Phase offset: adjustable in 0.1° steps.
Setting range: -145 dBm to +30 dBm (with electronic attenuator), -20 dBm to +30 dBm (without attenuator).
Resolution: 0.01 dB.
Possible modulation types: Amplitude modulation, frequency modulation, phase modulation, pulse modulation.
Internal modulation generator Frequency range: 0.1 Hz to 1 MHz.
Standard pulse generator Pulse period: 5 µs to 85 s.

Options.
SMA-B103, electronic attenuator.
SMA-B103L, without electronic attenuator.
SMA-B20, FM/phaseM Modulator.
SMA-B22, Enhanced Phase Noise Performance and FM/phaseM Modulator.
SMA-B29, Clock Synthesizer.
SMA-B80, Removable Mass Storage (compact flash disk).
SMA-B81, Rear Connectors.
SMA-K23, High-Performance Pulse Generator.
SMA-K24, Multifunction Generator.



 

Standard Calibration $920.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ SMA100A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your ROHDE & SCHWARZ SMA100A CALIBRATION and/or ROHDE & SCHWARZ SMA100A 3 GHz Signal Generator REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: