BK PRECISION 2831E CALIBRATION and BK PRECISION 2831E REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 2831E Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   BK PRECISION 2831E   Description / Specification:   Spec Sheet 
BK PRECISION 2831E 4 1/2 Digit True RMS Bench Multimeter

The B&K Precision 2831E is a versatile and dependable 4 1/2 digit bench multimeter suitable for applications in education, service and repair, and manufacturing requiring basic and reliable measurements. Additionally, this instrument enhances your productivity with built-in math functions and USB connectivity, math operations include; Rel, Max/Min, dBm, dB, %, and Hold. The 2831E take typical multimeter measurements such as volts, ohms, and amps with great accuracy, stability, and basic VDC accuracy of 0.03%. This meter is also capable of measuring frequency, period, continuity, and performing diode tests. Readings can be taken at a maximum rate of 25 readings/sec with measurement rates selectable between slow, medium, and fast. Dual display to indicate two measurements simultaneously. Specifications. DC Voltage Range: 200.00 mV, 2.0000 V, 20.000 V, 200.00 V, 1000.0 V. AC Voltage Range: 200.00 mV, 2.0000 V, 20.000 V, 200.00 V, 750.0 V. DC Current Range: 2.0000 mA, 20.000 mA, 200.00 mA, 2.0000 A, 20.000 A. AC Current Range (True RMS, AC Coupling): 2.0000 mA, 20.000 mA, 200.00 mA, 2.0000 A, 20.000 A. Resistance Ranges: 200.00 ohm, 2.0000 k-ohm, 20.000 k-ohm, 200.00 k-ohm, 2.0000 M-ohm, 20.000 M-ohm. Continuity: 200 ohm. Diode Test current: 0.5 mA (Approx.). Frequency Range: 10 Hz, 100 Hz, 100 kHz, 1 MHz. Period Range: 10 µs, 10 ms, 100 ms. Display Resolution: 20,000 count.



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 2831E. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your BK PRECISION 2831E CALIBRATION and/or BK PRECISION 2831E 4 1/2 Digit True RMS Bench Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: