BK PRECISION 4014B CALIBRATION and BK PRECISION 4014B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 4014B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   BK PRECISION 4014B   Description / Specification:   Spec Sheet 
BK PRECISION 4014B 12 MHz DDS Sweep Function Generators

The B&K Precision 4014B is a 12 MHz DDS (direct digital synthesis) function generator that generates stable and precise sine, square, and triangle waveforms. It provides variable output voltages from 0 to 10 Vpp into 50 ohms (up to 20 Vpp into open circuit), linear and logarithmic sweep, AM/FM modulation, built-in counter, and a continuously variable DC offset that allows the output to be injected directly into circuits at the correct bias level. Separate output amplitude and DC offset amplifiers let you set a large DC offset (e.g. ± 4.99 V ) with a small amplitude output signal (e.g. 10 mV). Specifications. Frequency Range: 0.01 Hz to 12 MHz (Sine, Square), 0.01 Hz to 1 MHz (Triangle). Resolution: 6 digits(square wave) or 10 mHz. Accuracy: 0.01% ± 0.006 Hz. Amplitude Range: 10 mVpp to 10 Vpp (into 50 ohms), 20 mVpp to 20 Vpp (open circuit). Amplitude Resolution: 3 digits (1,000 counts). Amplitude Accuracy: ± 2% ± 20 mV of programmed output from 1.01 V – 10 V. Flatness: ± 0.5 dB to 1 MHz, ± 1 dB to 12 MHz. Harmonic Distortion (for sine wave at 5 Vp-p into 50 ohms): < -60 dBc (0 – 1 MHz), <-50 dBc (1 MHz – 5 MHz), <-45 dBc (5 MHz – 12 MHz). Square Rise/Fall Time: <= 20 ns (10% to 90% at full amplitude into 50 ohms). Duty Cycle Square: 20% - 80% to 2 MHz. Duty Cycle Triangle: 1% - 99% in 1% steps, up to 200 kHz. Operating Modes: Continuous, Triggered, Gate, Burst, Trigger Source. Amplitude Modulation Internal: 0.1 Hz – 20 kHz sine only. Frequency Modulation Internal: 0.1 Hz – 20 kHz sine only. Counter Range: 50 Hz to 25 MHz. Counter Resolution: Auto ranging, up to 8 digits. Counter Accuracy ± 0.02% ± 2 digits. Memory Storage: 10 instrument settings.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 4014B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your BK PRECISION 4014B CALIBRATION and/or BK PRECISION 4014B 12 MHz DDS Sweep Function Generators REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: