BK PRECISION 4040B CALIBRATION and BK PRECISION 4040B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 4040B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   BK PRECISION 4040B   Description / Specification:   Spec Sheet 
BK PRECISION 4040B 20 MHz DDS Sweep Function Generators

The B&K Precision 4040B is a 20 MHz DDS (direct digital synthesis) function generator that generates stable and precise sine, square, and triangle waveforms. It provides variable output voltages from 0 to 10 Vpp into 50 ohms (up to 20 Vpp into open circuit), linear and logarithmic sweep, AM/FM modulation, built-in counter, and a continuously variable DC offset that allows the output to be injected directly into circuits at the correct bias level. Separate output amplitude and DC offset amplifiers let you set a large DC offset (e.g. ± 4.99 V ) with a small amplitude output signal (e.g. 10 mV). Specifications. Frequency Range: 0.01 Hz to 20 MHz (Sine, Square), 0.01 Hz to 2 MHz (Triangle). Resolution: 6 digits(square wave) or 10 mHz. Accuracy: 0.01% ± 0.006 Hz. Amplitude Range: 10 mVpp to 10 Vpp (into 50 ohms), 20 mVpp to 20 Vpp (open circuit). Amplitude Resolution: 3 digits (1,000 counts). Amplitude Accuracy: ± 2% ± 20 mV of programmed output from 1.01 V – 10 V. Flatness: ± 0.5 dB to 1 MHz, ± 1 dB to 20 MHz. Harmonic Distortion (for sine wave at 5 Vp-p into 50 ohms): < -60 dBc (0 – 1 MHz), <-50 dBc (1 MHz – 5 MHz), <-45 dBc (5 MHz – 12 MHz), <-50 dBc (12 MHz – 20 MHz). Square Rise/Fall Time: <= 20 ns (10% to 90% at full amplitude into 50 ohms). Duty Cycle Square: 20% - 80% to 2 MHz. Duty Cycle Triangle: 1% - 99% in 1% steps, up to 200 kHz. Operating Modes: Continuous, Triggered, Gate, Burst, Trigger Source. Amplitude Modulation Internal: 0.1 Hz – 20 kHz sine, square, or triangle waveform. Frequency Modulation Internal: 0.1 Hz – 20 kHz sine, square, or triangle waveform. Counter Range: 50 Hz to 25 MHz. Counter Resolution: Auto ranging, up to 8 digits. Counter Accuracy ± 0.02% ± 2 digits. Memory Storage: 20 instrument settings.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 4040B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your BK PRECISION 4040B CALIBRATION and/or BK PRECISION 4040B 20 MHz DDS Sweep Function Generators REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: