ELGAR 9012A REPAIR and ELGAR 9012A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ELGAR 9012A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ELGAR 9012A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   ELGAR 9012A (PIP 9012A)   Description / Specification:    
ELGAR 9012A Plug-In Programmable Oscillator for AC Power Source

The Elgar PIP 9012A Plug-In Programmer (PIP) is a microprocessor-based, multi-function system that features remote programming or local control via a 12-pad keyboard with display and function enunciators. The 9012A provides full GPIB control of simultaneous voltage and frequency and has a 1 to 9 full or half cycle dropout capability. With the test option, the front panel display becomes a digital meter to read the RMS volts, amps, watts and frequency. The PIP 9012A is ready to plug in to any of our full line of AC linear power sources. It is programmable via the IEEE-488 GPIB bus, or locally from the front panel keypad. Built-In Test (BIT) provides continuous self-testing for overvoltage, open sense leads and overcurrent. It shuts down the output voltage when any discrepancies occur between actual and programmed values. The output voltage is automatically programmed to zero during relay transfer time with off and on executed at zero crossings. This feature requires the ā€œDā€ option on the AC power source.
Specifications.

Frequency range (Programmable): 45 to 99.99 Hz, 45 to 999.9 Hz, 45 to 5000 Hz.
Resolution: 0.01/0.1/1.0 Hz.
Accuracy: 0.001% of Set Value.
Voltage Mode: Programmable, Simultaneously.
Voltage Range: 0-135 VAC, 0-270 VAC.
Resolution: 0.1 VAC.
Programming Accuracy: ±0.2% of Full Scale.



 

Standard Calibration $30.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ELGAR 9012A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your ELGAR 9012A REPAIR and/or ELGAR 9012A Plug-In Programmable Oscillator for AC Power Source CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: