ANRITSU MS2034B CALIBRATION and ANRITSU MS2034B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MS2034B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   ANRITSU MS2034B   Description / Specification:    
ANRITSU MS2034B 4 GHz VNA Master Handheld Vector Network/ Spectrum Analyzer

The Anritsu MS2034B VNA Master is a compact handheld solution to address cable, antenna, component, and signal analysis needs in the field. The VNA Master model offers benchtop accuracy and high performance S-parameter measurements in portable form. With frequency coverage from 500 kHz up to 4 GHz in a truly handheld, battery-operated, rugged, multi-function instrument, the VNA Master also provides a field-friendly touchscreen user interface.
Includes a spectrum analyzer which multiplies user convenience by combining both a VNA and a separate spectrum analyzer into a single measurement powerhouse for the harsh RF and physical environments of field test. Whether it is for spectrum monitoring, broadcast proofing, interference analysis, RF and microwave measurements, regulatory compliance, 3G/4G, Land Mobile Radio, or wireless data network measurements, this VNA/Spectrum Analyzer combination is the ideal instrument for making fast and reliable measurements in the field.
Specifications.

VNA.
Frequency Range: 500 kHz to 4 GHz.
Frequency Accuracy: 2.5 ppm.
Frequency Resolution: 1 Hz.
Test Port Power High Port Power:
  +3 dBm 500 kHz to < 3 GHz,
  0 dBm 3 GHz to 4 GHz.
Test Port Power Low Port Power: -25 dBm.
Maximum Input (Damage Level ) VNA Port 1 or 2: +23 dBm, ± 50 VDC.
Transmission Dynamic Range: 2 MHz to ≤ 4 GHz.
Sweep Speed (Typical): 500 kHz to 6 GHz, 850 μs/point.
Noise Floor:
  500 kHz to 3 GHz -100 dBm,
  3 GHz to 4 GHz -103 dBm.
Interference Immunity:
  On-Channel +17 dBm at > 1.0 MHz from carrier frequency,
  On-Frequency 0 dBm within ± 10 kHz of the carrier frequency.

Measurements.
Measurement Parameters: S11, S21.
Number of Traces Four: TR1, TR2, TR3, TR4.
Domains: Frequency Domain, Distance Domain.
Frequency: Start Frequency, Stop Frequency, Center Frequency, Span.
Distance: Start Distance, Stop Distance.
Frequency Sweep Type Linear: Single Sweep, Continuous.
Data Points: 2 to 4001 (arbitrary setting); data points can be reduced without recalibration.

Spectrum Analyzer.
Frequency Range: 9 kHz to 4 GHz (tunable to 0 Hz).
Tuning Resolution: 1 Hz.
Frequency Span: 10 Hz to 4 GHz including zero span.
Sweep Time Minimum: 100 ms, 7 μs to 3600 s in zero span.
Resolution Bandwidth (RBW): 10 Hz to 3 MHz in 1-3 sequence ± 10% (1 MHz max in zero-span) (-3 dB bandwidth).
Video Bandwidth (VBW): 1 Hz to 3 MHz in 1-3 sequence (-3 dB bandwidth) (auto or manually selectable).
Dynamic Range: > 102 dB (2.4 GHz), 2/3 (TOI-DANL) in 1 Hz RBW.
Reference Level Range: -150 dBm to +30 dBm.
Attenuator Range: 0 dB to 55 dB in 5 dB steps.
Maximum Continuous Input: +30 dBm.

Options.
-0010 Built-in Bias-Tee, +12 V to +32 V variable.
-0015 Vector Voltmeter.
-0019 High Accuracy Power Meter (requires external USB sensor, sold separately).
-0025 Interference Analyzer.
-0027 Channel Scanner.
-0031 GPS Receiver.
-0431 Coverage Mapping.
-0509 AM/FM/PM Demodulation Analyzer.



 

Standard Calibration $700.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MS2034B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Standing Wave Ratio (SWR)
Standing wave ratio (SWR) is the ratio of the amplitude of a partial standing wave at an antinode (maximum) to the amplitude at an adjacent node (minimum).


Please contact us for your ANRITSU MS2034B CALIBRATION and/or ANRITSU MS2034B 4 GHz VNA Master Handheld Vector Network/ Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: