A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX DPO72004C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX DPO72004C   Description / Specification:   Spec Sheet 
TEKTRONIX DPO72004C 4 Ch 20 GHz Digital Phosphor Oscilloscope

The Tektronix DPO72004C with 4 analog channels has a high signal-to-noise ratio and low internal noise floor. It allows you to find the smallest anomalies affecting the DUT's performance. Bandwidth enhancement eliminates imperfections in frequency response all the way to the probe tip. User-selectable filters for each channel provide magnitude and phase correction for more accurate representation of extremely fast signals. 
Specifications.

Analog channels: 4.
Analog bandwidth (user-selectable DSP enhance) (-3 dB): 20 GHz.
Hardware Analog Bandwidth (-3 dB): 4 GHz).
Rise time (typical): 18 ps (10% to 90%), 14 ps (20% to 80%).
Sample rate (1, 2 ch): 100 GS/s (maximum sample rate is 50 GS/s on digital channels routed to an analog channel through the iCapture™ analog mux).
Sample rate (3, 4 ch): 50 GS/s.
Record length, points (each channel, standard): 10 M. 
Timing resolution: 10 ps (100 GS/s).

Vertical system - Analog channels.
DC gain accuracy: ±2% (of reading).
Channel delay (typical): <=10 ps for any two channels at equal V/div and coupling.
Signal-to-Noise ratio (typical): 34 dB.
Input coupling: DC (50 Ω), GND.
Input resistance selection: 50 Ω ±3%, 1 MΩ with TCA-1MEG adapter.
Input sensitivity range: 10 mV/div to 500 mV/div (100 mV to 5 V full scale).
Maximum input voltage, 50 Ω: <5.0 VRMS for >=100 mV/div; 1.0 VRMS for <100 mV/div. 

Horizontal system.
Channel-to-Channel: deskew range ±75 ns.
Time base accuracy: ±1.5 ppm initial accuracy, aging <1 ppm per year.
Time base delay time range: -5.0 ks to 1.0 ks.
Trigger jitter: <100 fsRMS (1 psRMS [typical] with enhanced triggering off).



 

Standard Calibration $415.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX DPO72004C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your TEKTRONIX DPO72004C CALIBRATION and/or TEKTRONIX DPO72004C 4 Ch 20 GHz Digital Phosphor Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: