FLUKE 1550C REPAIR and FLUKE 1550C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the FLUKE 1550C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 1550C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   FLUKE 1550C   Description / Specification:    
FLUKE 1550C 5 kV Insulation Tester

The Fluke 1550C Insulation Tester performs digital insulation testing up to 5 kV. It features remote operation, real-time trending, and can create reports quickly, using pre-designed templates that you can customize with company logos. It’s the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. It has a CAT IV 600 V safety rating.

Insulation Resistance Measurement Test voltage (DC).
250 V.
  Range: < 250 kΩ, 250 kΩ to 5 GΩ, 5 GΩ to 50 GΩ, > 50 GΩ.
  Accuracy (± reading): Unspecified, 5%, 20%, Unspecified.
500 V.
  Range: < 500 kΩ, 500 kΩ to 10 GΩ, 10 GΩ to 100 GΩ, > 100 GΩ.
   Accuracy (± reading): Unspecified, 5%, 20%, Unspecified.
1000 V.
  Range: < 1 MΩ, 1 MΩ to 20 GΩ, 20 GΩ to 200 GΩ, > 200 GΩ.
  Accuracy (± reading): Unspecified, 5%, 20%, Unspecified.
2500 V.
  Range: < 2.5 MΩ, 2.5 MΩ to 50 GΩ, 50 GΩ to 500 GΩ, > 500 GΩ.
  Accuracy (± reading): Unspecified, 5%, 20%, Unspecified.
5000 V.
  Range: < 5 MΩ, 5 MΩ to 100 GΩ, 100 GΩ to 1 TΩ, > 1 TΩ.
  Accuracy (± reading): Unspecified, 5%, 20%, Unspecified.

Additional Specifications.
Bar graph range: 0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555).
Insulation test voltage accuracy: -0%, +10% at 1 mA load current.
Induced AC mains current rejection: 2 mA maximum.
Charging rate for capacitive load: 5 seconds per μF.
Discharge rate for capacitive load: 1.5 s/μF.
Leakage current measurement.
  Range: 1 nA to 2 mA.
  Accuracy: ± (5% + 2 nA).
Capacitance measurement.
  Range: 0.01 μF to 15.00 μF.
  Accuracy: ± (15% rdg + 0.03 μF).
Timer.
  Range: 0 to 99 minutes.
  Resolution setting: 1 minute.
  Resolution indication: 1 second.
Live circuit warning.
  Warning range: 30 V to 660 V AC/DC, 50/60 Hz.
  Voltage accuracy: ± (15% + 2 V).



 

Standard Calibration $520.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 1550C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your FLUKE 1550C REPAIR and/or FLUKE 1550C 5 kV Insulation Tester CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: