YOKOGAWA WT1806 CALIBRATION and YOKOGAWA WT1806 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA WT1806 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   YOKOGAWA WT1806   Description / Specification:    
YOKOGAWA WT1806 Six Input Element High Performance Power Analyzer

The Yokogawa WT1806 Six Input Element High Performance Power Analyzer has innovative functions that help improve measurement efficiency; Motor, Inverter, Lighting, EV/HEV, Battery, Power Supply, Aircraft, New Energy, Power Conditioner. Direct input of measurement signals makes it possible to measure very small current that can hardly be measured with a current sensor. The WT1806 provides a direct input voltage range from 1.5 V to 1000 V (12 ranges) and a direct input current range from 10 mA to 5 A (9 ranges) or from 1 A to 50 A (6 ranges). The frequency lower limit has been reduced to 0.1 Hz from the previous 0.5 Hz (5-fold lower than the previous model) to meet the requirement for power measurements at a low speed. Furthermore, high-speed data collection at a data update rate of up to 50 ms has been inherited. In addition to normal measurement data, up to the 500th order harmonic data can be measured and saved simultaneously. The data update rate can be selected from nine options from 50 ms to 20 s. Specifications. Basic power accuracy (50/60Hz): 0.1% of reading + 0.05% of range. Power frequency range: DC, 0.1 Hz ~ 1 MHz. Input elements: 6. Voltage range: 1.5/ 3/ 6/ 10/ 15/ 30/ 60/ 100/ 150/ 300/ 600/ 1000 [V]. Current range (direct input): 10m/ 20m/ 50m/ 100m/ 200m/ 500m/ 1/ 2/ 5 [A] or 1/ 2/ 5/ 10/ 20/ 50 [A]. Current range (external sensor input): 50m/ 100m/ 250m/ 500/ 1/ 2.5/ 5/ 10 [V]. Guaranteed accuracy range for voltage and current: 1% to 110%. Basic voltage/current accuracy: +/-0.1%. Basic power accuracy: +/-0.05%. Frequency range: DC, 0.1Hz to 1 MHz. Voltage/Current frequency range (-3 dB, typical): 5 MHz. Sampling speed: approximately 2 MS/s. Data update rate: 50 m, 100 m, 200 m, 500 m, 1, 2, 5, 10, 20 [sec]. Line filter: OFF, digital filter 100 Hz to 100 kHz (100 Hz step) analog filter 300 kHz, 1 MHz. Frequency filter: OFF, 100 Hz or 1 kHz. Fundamental frequency of the PLL source: 0.5 Hz to 2600 Hz (internal sampling clock), without external sampling clock function. Display: 8.4-inch color TFT LCD display, Total number of pixels* 1024 (horizontal) × 768 (vertical) dots. Options. /EX6, External current sensor input. /B5, Built-in printer. /G5, Harmonic Measurement. /G6, Simltaneous Dual Harmonic Measurement. /DT, Delta Computation. /FQ, Add-on Frequency Measurement. /V1, RGB output. /DA, 20-channel DA Outputs. /MTR, Motor Evaluation Function. /AUX, Auxiliary Sensor Inputs. /HS, High speed data capturing.



 

Standard Calibration $760.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA WT1806. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your YOKOGAWA WT1806 CALIBRATION and/or YOKOGAWA WT1806 Six Input Element High Performance Power Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: