DESCO 19493 CALIBRATION and DESCO 19493 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DESCO 19493 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   DESCO 19493   Description / Specification:    
DESCO 19493 Ionization Test Kit

The Desco 19493 Ionization Test Kit allows the 19492 Digital Static Field Meter to be used to measure the offset voltage (balance) and charge decay of ionization equipment. The Test Kit also includes a Charger used to place a ±1000V charge on the 19498 Conductive Plate, making it possible to also measure the discharge times of air ionization equipment per ANSI/ESD SP3.3 Periodic Verification of Air Ionizers. The 19493 Ionization Test Kit includes the 19492 Digital Static Field Meter, providing a highly portable and cost effective means of verifying the performance of a wide variety of ionization equipment. The analog output jack labeled “OUT” on the face of the Meter accepts a standard 2.5 mm monaural phone plug and is provided so the output of the Digital Static Field Meter may be connected to an oscilloscope, strip chart recorder, external meter or other device. Specifications. Measurement Range (switch selectable): 0 to ±1.99 kV / inch (Low Range), 0 to ±19.99 kV / inch (High Range). Measurement Accuracy Voltage Monitor Output: > ±5% of reading ±10 mV. Measurement Accuracy Voltage Display: > ±5% of reading ±2 counts. Measurement Stability: ±10 counts.



 

Standard Calibration $245.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the DESCO 19493. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your DESCO 19493 CALIBRATION and/or DESCO 19493 Ionization Test Kit REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: