ANRITSU MA24108A CALIBRATION and ANRITSU MA24108A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ANRITSU MA24108A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   ANRITSU MA24108A   Description / Specification:   Spec Sheet 
ANRITSU MA24108A 8 GHz, True-RMS, USB Power Sensor

The Anritsu MA24108A 8 GHz USB Power Sensor is designed to provide accurate average power measurements from 10 MHz to 8 GHz over 60 dB of dynamic range. It employs a "dual path" architecture that provides (similar to thermal sensor) True-RMS measurements over the entire frequency and dynamic range, enabling users to make highly accurate average power measurements for CW, multi-tone, and digitally modulated signal up to 8 GHz. The sensor has internal and external triggering capability that facilitates individual slot power measurements of TDMA waveforms as well as burst power measurements of periodic and non-periodic waveforms.

Specifications.
Frequency Range: 10 MHz to 8 GHz.
Dynamic Range: -40 dBm to +20 dBm.
SWR:
  <1.17 (10 MHz to 150 MHz),
  <1.12 (150 MHz to 2 GHz),
  <1.22 (2 GHz to 8 GHz).
Signal channel rise time: 8 µs typical.
Video bandwidth: 50 kHz typical.
Sampling rate: 140 ks/s, typical.
Measurement ranges:
  Range 1, +20 dBm to -7 dBm typical;
  Range 2, -7 dBm to -40 dBm typical;
  Auto ranging between range 1 and 2.
Linearity: <3%.
Noise:
  < 8 µW, Range 1;
  < 40 nW, Range 2.
RF Connector: N (m).



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ANRITSU MA24108A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your ANRITSU MA24108A CALIBRATION and/or ANRITSU MA24108A 8 GHz, True-RMS, USB Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: