NATIONAL INSTRUMENTS PXIE-4141 CALIBRATION and NATIONAL INSTRUMENTS PXIE-4141 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the NATIONAL INSTRUMENTS PXIE-4141 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   NATIONAL INSTRUMENTS PXIE-4141   Description / Specification:    
NATIONAL INSTRUMENTS PXIE-4141 4Ch Precision Source/Measure Unit (SMU) 10V, 100mA

The National Instruments PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
Specifications.

Settling time: <100 μs to settle to 0.1% of voltage step, device configured for fast transient response, typical.
Transient response: <100 μs to recover within ±20 mV after a load current change from 10% to 90% of range, device configured for fast transient response, typical.
Wideband source noise: 1.5 mV RMS, typical, <20 mVpk-pk, typical.
Cable guard output impedance: 10 kΩ, typical.

Voltage Programming and Measurement Accuracy/Resolution.
Range | Resolution and noise (0.1 Hz to 10 Hz) | Accuracy (23 °C ± 5 °C) ± (% of voltage + offset) | Tempco ± (% of voltage + offset)/°C, 0 °C to 55 °C.
  10 V | 10 μV | 0.015% + 600 μV (Tcal ± 5 °C) |0.0005% + 1 μV.

Current Programming and Measurement Accuracy/Resolution.
Range | Resolution and noise (0.1 Hz to 10 Hz) | Accuracy (23 °C ± 5 °C) ± (% of current + offset) | Tempco ± (% of current + offset)/°C, 0 °C to 55 °C.
  10 μA |10 pA |0.03% + 1.5 nA (Tcal ± 5 °C) | 0.002% + 10 pA,
  100 μA | 100 pA | 0.03% + 15 nA (Tcal ± 5 °C) | 0.002% + 100 pA,
  1 mA | 1 nA | 0.03% + 150 nA (Tcal ± 5 °C) | 0.002% + 1.0 nA,
  10 mA | 10 nA | 0.03% + 1.5 μA (Tcal ± 5 °C) | 0.002% + 10 nA,
  100 mA | 100 nA | 0.03% + 15 μA (Tcal ± 5 °C) | 0.002% + 00 nA.

Output Resistance Programming Accuracy/Resolution, Typical.
Current limit range | Programmable resistance range |Resolution | Accuracy ± (% of resistance setting), Tcal ± 5 °C.
  10 μA | ± 100 kΩ | 1.0 Ω | 0.04% + 510 mΩ,
  100 μA | ± 10 kΩ | 100 mΩ | 0.04% + 60 mΩ,
  1 mA | ± 1 kΩ | 10 mΩ | 0.04% + 15 mΩ,
  10 mA | ± 100 Ω | 1 mΩ | 0.04% + 10 mΩ,
  100 mA | ± 10 Ω | 100 μΩ | 0.04% + 10 mΩ.



 

Standard Calibration $1,955.00 *
*This is a Web introductory price for one calibration of the NATIONAL INSTRUMENTS PXIE-4141. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your NATIONAL INSTRUMENTS PXIE-4141 CALIBRATION and/or NATIONAL INSTRUMENTS PXIE-4141 4Ch Precision Source/Measure Unit (SMU) 10V, 100mA REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?