NATIONAL INSTRUMENTS PXIE-4141 CALIBRATION and NATIONAL INSTRUMENTS PXIE-4141 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the NATIONAL INSTRUMENTS PXIE-4141 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   NATIONAL INSTRUMENTS PXIE-4141   Description / Specification:    
NATIONAL INSTRUMENTS PXIE-4141 4Ch Precision Source/Measure Unit (SMU) 10V, 100mA

The National Instruments PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
Specifications.

Settling time: <100 μs to settle to 0.1% of voltage step, device configured for fast transient response, typical.
Transient response: <100 μs to recover within ±20 mV after a load current change from 10% to 90% of range, device configured for fast transient response, typical.
Wideband source noise: 1.5 mV RMS, typical, <20 mVpk-pk, typical.
Cable guard output impedance: 10 kΩ, typical.

Voltage Programming and Measurement Accuracy/Resolution.
Range | Resolution and noise (0.1 Hz to 10 Hz) | Accuracy (23 °C ± 5 °C) ± (% of voltage + offset) | Tempco ± (% of voltage + offset)/°C, 0 °C to 55 °C.
  10 V | 10 μV | 0.015% + 600 μV (Tcal ± 5 °C) |0.0005% + 1 μV.

Current Programming and Measurement Accuracy/Resolution.
Range | Resolution and noise (0.1 Hz to 10 Hz) | Accuracy (23 °C ± 5 °C) ± (% of current + offset) | Tempco ± (% of current + offset)/°C, 0 °C to 55 °C.
  10 μA |10 pA |0.03% + 1.5 nA (Tcal ± 5 °C) | 0.002% + 10 pA,
  100 μA | 100 pA | 0.03% + 15 nA (Tcal ± 5 °C) | 0.002% + 100 pA,
  1 mA | 1 nA | 0.03% + 150 nA (Tcal ± 5 °C) | 0.002% + 1.0 nA,
  10 mA | 10 nA | 0.03% + 1.5 μA (Tcal ± 5 °C) | 0.002% + 10 nA,
  100 mA | 100 nA | 0.03% + 15 μA (Tcal ± 5 °C) | 0.002% + 00 nA.

Output Resistance Programming Accuracy/Resolution, Typical.
Current limit range | Programmable resistance range |Resolution | Accuracy ± (% of resistance setting), Tcal ± 5 °C.
  10 μA | ± 100 kΩ | 1.0 Ω | 0.04% + 510 mΩ,
  100 μA | ± 10 kΩ | 100 mΩ | 0.04% + 60 mΩ,
  1 mA | ± 1 kΩ | 10 mΩ | 0.04% + 15 mΩ,
  10 mA | ± 100 Ω | 1 mΩ | 0.04% + 10 mΩ,
  100 mA | ± 10 Ω | 100 μΩ | 0.04% + 10 mΩ.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your NATIONAL INSTRUMENTS PXIE-4141 CALIBRATION and/or NATIONAL INSTRUMENTS PXIE-4141 4Ch Precision Source/Measure Unit (SMU) 10V, 100mA REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: