NATIONAL INSTRUMENTS PXIE-4141 CALIBRATION and NATIONAL INSTRUMENTS PXIE-4141 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the NATIONAL INSTRUMENTS PXIE-4141 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   NATIONAL INSTRUMENTS PXIE-4141   Description / Specification:    
NATIONAL INSTRUMENTS PXIE-4141 4Ch Precision Source/Measure Unit (SMU) 10V, 100mA

The National Instruments PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
Specifications.

Settling time: <100 μs to settle to 0.1% of voltage step, device configured for fast transient response, typical.
Transient response: <100 μs to recover within ±20 mV after a load current change from 10% to 90% of range, device configured for fast transient response, typical.
Wideband source noise: 1.5 mV RMS, typical, <20 mVpk-pk, typical.
Cable guard output impedance: 10 kΩ, typical.

Voltage Programming and Measurement Accuracy/Resolution.
Range | Resolution and noise (0.1 Hz to 10 Hz) | Accuracy (23 °C ± 5 °C) ± (% of voltage + offset) | Tempco ± (% of voltage + offset)/°C, 0 °C to 55 °C.
  10 V | 10 μV | 0.015% + 600 μV (Tcal ± 5 °C) |0.0005% + 1 μV.

Current Programming and Measurement Accuracy/Resolution.
Range | Resolution and noise (0.1 Hz to 10 Hz) | Accuracy (23 °C ± 5 °C) ± (% of current + offset) | Tempco ± (% of current + offset)/°C, 0 °C to 55 °C.
  10 μA |10 pA |0.03% + 1.5 nA (Tcal ± 5 °C) | 0.002% + 10 pA,
  100 μA | 100 pA | 0.03% + 15 nA (Tcal ± 5 °C) | 0.002% + 100 pA,
  1 mA | 1 nA | 0.03% + 150 nA (Tcal ± 5 °C) | 0.002% + 1.0 nA,
  10 mA | 10 nA | 0.03% + 1.5 μA (Tcal ± 5 °C) | 0.002% + 10 nA,
  100 mA | 100 nA | 0.03% + 15 μA (Tcal ± 5 °C) | 0.002% + 00 nA.

Output Resistance Programming Accuracy/Resolution, Typical.
Current limit range | Programmable resistance range |Resolution | Accuracy ± (% of resistance setting), Tcal ± 5 °C.
  10 μA | ± 100 kΩ | 1.0 Ω | 0.04% + 510 mΩ,
  100 μA | ± 10 kΩ | 100 mΩ | 0.04% + 60 mΩ,
  1 mA | ± 1 kΩ | 10 mΩ | 0.04% + 15 mΩ,
  10 mA | ± 100 Ω | 1 mΩ | 0.04% + 10 mΩ,
  100 mA | ± 10 Ω | 100 μΩ | 0.04% + 10 mΩ.



 

Standard Calibration $1,955.00 *
*This is a Web introductory price for one calibration of the NATIONAL INSTRUMENTS PXIE-4141. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your NATIONAL INSTRUMENTS PXIE-4141 CALIBRATION and/or NATIONAL INSTRUMENTS PXIE-4141 4Ch Precision Source/Measure Unit (SMU) 10V, 100mA REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: