HIOS HP-100 CALIBRATION and HIOS HP-100 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the HIOS HP-100 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   HIOS HP-100   Description / Specification:    
HIOS HP-100 1.5-90 in-lb Digital Torque Tester

The HIOS HP-100 Digital Torque Tester is used for making torque settings on electric drivers, checking torque of torque wrenches or measuring torque of fasteners. Features analog or data signal in Mitutoyo format. Optional adaptor and cable needed to connect to PC. Reads clockwise or counterclockwise with equal accuracy. Max, Min and Avg given of last 10 readings. Runs on rechargeable Ni-MH batteries. Specification. Power measuring range: 0.15 - 10.00 Newton-meters, 1.5 - 90.0 inch-pounds, 1.5-100.0 kilogram-force centimeter. Accuracy: Up to ±0.5%(fullscreen). Measuring modes: track,peak, first peak. Continuous running time on a full charge: 8 hours.



 

Standard Calibration $330.00 *
*This is a Web introductory price for one calibration of the HIOS HP-100. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your HIOS HP-100 CALIBRATION and/or HIOS HP-100 1.5-90 in-lb Digital Torque Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: