HIOS HP-10 CALIBRATION and HIOS HP-10 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the HIOS HP-10 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   HIOS HP-10   Description / Specification:    
HIOS HP-10 0.15-9.00 in-lb Digital Torque Tester

The HIOS HP-10 Digital Torque Tester is used for making torque settings on electric drivers, checking torque of torque wrenches or measuring torque of fasteners. Features analog or data signal in Mitutoyo format. Optional adaptor and cable needed to connect to PC. Reads clockwise or counterclockwise with equal accuracy. Max, Min and Avg given of last 10 readings. Runs on rechargeable Ni-MH batteries. Specification. Power measuring range: 0.015 - 1.000 Newton-meters, 0.15 - 9.00 inch-pounds, 0.15-10.00 kilogram-force centimeter. Accuracy: Up to ±0.5%(fullscreen). Measuring modes: track,peak, first peak. Continuous running time on a full charge: 8 hours.



 

Standard Calibration $330.00 *
*This is a Web introductory price for one calibration of the HIOS HP-10. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your HIOS HP-10 CALIBRATION and/or HIOS HP-10 0.15-9.00 in-lb Digital Torque Tester REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: