A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK LCR-816 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK LCR-816   Description / Specification:    
INSTEK LCR-816 2 kHz Precision LCR Meter

The GW Instek LCR-816 is a high-end digital LCR meter for component/material measurements, applicable to various R&D activities and assembly lines. The large 240 x 128 dot matrix LCD display provides ample room for two measurement items and setup parameters. All test modes are able to measure supplementary factors, such as, R/Q, C/D, C/R, and L/Q. 100 sets of measurement setup memory allow sharing a single unit among multiple testing conditions or sites. For a better viewing experience in a standard PC monitor, proprietary Windows based software is accessible via the RS-232C terminal (optional). Specifications. Test Frequency: 100 Hz to 2 kHz (245 steps). Basic Accuracy: 0.1%. Test Speed: 68 ms. Test Signal Levels: 0.1 V to 1.275 Vrms ( 5 mV/step ). DC Bias Internal: 2 V. DC Bias External: 0 to 30 V. Display Range Resistance: 0.00001 ohm to 99999 k-ohm. Display Range Capacitance: 0.00001 pF to 99999 uF. Display Range Inductance: 0.00001 mH to 99999 H. Test Mode: R/Q, C/D, C/R, L/Q. Memory: 100 memory blocks total.



 

Standard Calibration $150.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK LCR-816. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your INSTEK LCR-816 CALIBRATION and/or INSTEK LCR-816 2 kHz Precision LCR Meter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: